14.18.1 Minimum Input level fo.
录入:edatop.com 点击:
14.18.1 Minimum Input level for Reference Performance测试不过,有没有哪位工程师遇到过,怎么解决的呢?
下面是测试信息,哪位解决过,给分享一下啊
Testcase feasibility : All
Channel : PDTCH/MCS-8
Power Control Level : Max
DL Level Reference : Reference Sens. + Value
DL Level of DCH (1 slot) : 23.0 dBc
Absolute level at DUT input : -79.0 dBm
ARFCN : 660
Hopping : False
Loopback : None
Fading Profile : TU
Fading Speed : 50.0 km/h
Int1 Signal : None
Int2 Signal : None
Temperature : Normal
Voltage : Normal
Rx Result Rate : 20 s
Meas 1 Type : GPRS BCS
Meas 1 Samples : 8000
Meas 1 Limit : 30.0000 %
换 For multislot class 10 used TX slot :5
换 For multislot class 10 used RX slots:3, 4, 5, 6
换 Setting SSCU Path: rf_out;dut_tx_rx;rv0040
换 Setting the climatic chamber to25.0 C
TEST ERROR SAMPLES ERROR ERROR INTERIM
STEP TYPE MEASURED RATE LIMIT RESULT
2 GPRS BCS 8000 31.0125 30.0000 Outside
下面是测试信息,哪位解决过,给分享一下啊
Testcase feasibility : All
Channel : PDTCH/MCS-8
Power Control Level : Max
DL Level Reference : Reference Sens. + Value
DL Level of DCH (1 slot) : 23.0 dBc
Absolute level at DUT input : -79.0 dBm
ARFCN : 660
Hopping : False
Loopback : None
Fading Profile : TU
Fading Speed : 50.0 km/h
Int1 Signal : None
Int2 Signal : None
Temperature : Normal
Voltage : Normal
Rx Result Rate : 20 s
Meas 1 Type : GPRS BCS
Meas 1 Samples : 8000
Meas 1 Limit : 30.0000 %
换 For multislot class 10 used TX slot :5
换 For multislot class 10 used RX slots:3, 4, 5, 6
换 Setting SSCU Path: rf_out;dut_tx_rx;rv0040
换 Setting the climatic chamber to25.0 C
TEST ERROR SAMPLES ERROR ERROR INTERIM
STEP TYPE MEASURED RATE LIMIT RESULT
2 GPRS BCS 8000 31.0125 30.0000 Outside
周总,怎么又在测这个东西了
搂住,我还没跑过这个test case,eGPRG的还没跑过...
我现在主要是在做wcdma的一些测试。我刚有一个问题,5.7: Power setting in UL compressed mode;
也遇到一些问题,搂住能不能给我看看?
谢谢。
fredwill: 哈哈,搞不完了
申明:网友回复良莠不齐,仅供参考。