关于GSM手机功率/时间模板fail
其实送去作CTA的机器最好在校准的基础上进一步优化一下射频参数,防止出现由于测试系统不同而出现的意外。
可我测量的结果的冗余度是很大的,而CTA的测试结果也不是超标而是Unable to measure ,我可有些摸不着头脑了
能把CTA的测试数据拿来吗?
ARFCN=1 测得值 下限 上限TX powererror @ lvl 7 -0.4 -2 2 TXtimingeroor 2.67T -1 1 failTX ampl envelope @ -28us Unable to measure -70.00 failTX ampl envelope @ -18us -41.94 -30.00TX ampl envelope @ -10us -12.56 -6.00TX ampl envelope @ +10us -19.64 -6.00TX ampl envelope @ +18us -43.57 -30.00TX ampl envelope @ +28us Unable to measure -70.00 fail各信道GSM/DCS段均类次
Something must be wrong with synchronization of the burst, check your ramping mask performance in both amplitude and midamble synchronization mode in 8960.
If there is no problem, I am afraid there are some software or protocol incompatible.
There is another possibility that the 8922 met some trouble, I met similar troubles before on 8960.
tell them the result on your own instrument.maybe the 8960 or cmu needs calibration.(1 cal 1 day)
什么是8960的amplitude and midamble synchronization mode?
申明:网友回复良莠不齐,仅供参考。
上一篇:RF电路不动作如何DEBUG