- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
如何将MAX layers 换成普通层?
可以帮下吗?
不可以
不能换吧
Layer Modes
PADS Layout supports two layer modes, default layer mode and increased layer mode. When a design is in default layer mode, the maximum number of layers is 30. When a design is in increased layer mode, the maximum number of layers is 250. In increased layer mode, the maximum number of electrical layers is 64 and the maximum number of nonelectrical layers is 186.You change from default layer mode to increased layer mode by clicking the Max Layers button in the Layers Setup dialog box. Changing from default layer mode to increased layer mode reassigns all nonelectrical data by increasing all nonelectrical layer numbers by 100. Once you change the design to increased layer mode, you cannot return to default layer mode.Layer 25 is used to define the pad oversize for thermals and antipads on CAM (photographic negative) planes.See also: "Layer Modes" topic in the "Designing" chapter of the ? 2005 Mentor Graphics Corp. All Rights Reserved.
From PADS Layout Concepts Guide:Layer Modes
PADS Layout supports two layer modes: default layer mode (30 layers) and increased layer mode
(up to 250 layers). In default layer mode, the 30 layer maximum can consist of up to a maximum
of 30 electrical layers or a combination of electrical and nonelectrical layers. In increased layer
mode, the maximum number of electrical layers is 64 and the maximum number of nonelectrical
layers is 186, for a total of 250 layers. The total number of layers includes associated layers such as
mask, silk screen, drill drawing, and assembly layers.
You change from default layer mode to increased layer mode by clicking the Max Layers button in
the Layers Setup dialog box. Changing from default layer mode to increased layer mode increases
all nonelectrical layer numbers by 100.
Restriction: Once you change the design to increased layer mode, you cannot return to default
layer mode.
In default layer mode, layer number 20 is used for placement outlines. In increased layer mode,
layer 120 is used for placement outlines. Layer 25 in default layer mode, or 125 in increased layer
mode, is used for oversizing thermals and antipads.
In default layer mode, you can only import, add, or load other default layer mode items, such as
files or library items, to your design. You cannot load increased layer mode objects into the default
layer mode design. In increased layer mode, you can load both default and increased layer mode
objects into your design.
Restriction: You cannot export a design with more than 30 electrical layers to a PADS Layout
PADS-format ASCII file prior to version 4.0.
You don't have to convert existing default layer mode libraries, reuse files, or archived designs to
increased layer mode. You can use existing library decals, drawings, and reuses that are saved in
default layer mode for both default and increased layer mode designs. You can cut from a design in
default layer mode and paste into a design in increased layer mode. If you make sure that you have
consistent layer definition in libraries, reuses, and designs, no problems with layer matching will
occur.
Either default or increased layer mode is specified in each design or design fragment such as .pcb,
.asc, .stp, .dxf, .reu, and high speed .edp files, library decals and drawing items, copy/paste buffer,
and external CAM documents.
有谁知道呀,求解
导成低版本的
转换到大层以后,转换不了到小层模式
转成PADS3。0的就行
射频工程师养成培训教程套装,助您快速成为一名优秀射频工程师...
天线设计工程师培训课程套装,资深专家授课,让天线设计不再难...
上一篇:Protel 到PADS转换程序
下一篇:如何让元器件放置在板框上