• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > ADS > ADS使用问答 > ADS EM仿真遇到的问题

ADS EM仿真遇到的问题

录入:edatop.com    点击:

那请问你知道开始那些提示是什么原因造成的吗?

我在优化稳定性系数时也遇到了这个错误,找不出原因:
   The simulation temperature (25.0 C) is not the same as the IEEE standard
    noise temperature (290 K or 16.85 C) in the noise analysis `SP1'.
    If the simulation temperature is not equal to the IEEE standard temperature,
    then the loss and the noise figure will not agree for a passive circuit.
    The `Temp' parameter on the Options item can be set to 16.85 C to
    eliminate this warning message.

Simulation / Synthesis Messages
Warning detected by hpeesofsim during TRAN analysis `SP1'.
    COMPONENT `X4_LNA_schematic_13_1':
       Simulator uses frequency lower than frequency range of Momentum model. The S-parameters are extrapolated.
Warning detected by hpeesofsim during TRAN analysis `SP1'.
    COMPONENT `X4_LNA_schematic_13_1':
       The model for the Layout Component is not found in the ModelDatabase, a new model is generated for the requested parameter values.
Warning detected by hpeesofsim during TRAN analysis `SP1'.
    COMPONENT `X4_LNA_schematic_13_1':
       The model for the Layout Component is reused from the ModelDatabase.
Warning detected by hpeesofsim during SP analysis `SP1'.
    The simulation temperature (25.0 C) is not the same as the IEEE standard
    noise temperature (290 K or 16.85 C) in the noise analysis `SP1'.
    If the simulation temperature is not equal to the IEEE standard temperature,
    then the loss and the noise figure will not agree for a passive circuit.
    The `Temp' parameter on the Options item can be set to 16.85 C to
    eliminate this warning message.
仿真几个小时之后给出这个提示,仿真结果S21为负值,噪声到70多最小噪声也是70多,请教是什么地方错误造成的,非常感谢。

这个问题有解决的吗

s参数的option里面第一个温度设为16.85

申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程

上一篇:ADS2008射频电路设计与仿真实例LNA章节求解,请做过的童鞋帮帮忙
下一篇:一个很好的ADS学习网站

ADS培训课程推荐详情>>