各位大侠,我经常遇到在layout进行场仿真后(仿真和结果顺利进行,无报错),但是在拉入到电路仿真s参数时候,报错如下,求教!


重贴一下报错内容:
Simulation / Synthesis Messages
Warning detected by hpeesofsim in topology check during circuit set up.
    Number of nodes with only one device attached (topology corrected): 5
    Number of nodes with no DC path to ground (topology corrected): 19
Error detected by hpeesofsim during TRAN analysis 'SP1'.
    `test_1': S-parameters are not available at 0 Hz.
Error detected by hpeesofsim during TRAN analysis 'SP1'.
    Fatal error occurred while evaluating model `MomCmpt', instance `test_1'.
Status / Summary

hpeesofsim (*) 331.200 May  6 2008 (built: 05/06/08 00:26:15)
Copyright Agilent Technologies, 1989-2008.
******************************************
***** Abnormal Simulator Termination *****
******************************************
The simulator has unexpectedly terminated.

可能是你在layout下的频率设置和schematic下的不同。

频率设成一直也不管用啊,那位高手帮忙解答胰一下怎么化解啊?
Simulation / Synthesis Messages
Warning detected by hpeesofsim in topology check during circuit set up.
    Number of nodes with only one device attached (topology corrected): 10
Error detected by hpeesofsim during SP analysis 'SP1'.
    `X090224_output_1': Syntax error in the Layout Component ModelDatabase citi-file.
Error detected by hpeesofsim during SP analysis 'SP1'.
    Fatal error occurred while evaluating model `MomCmpt', instance `X090224_output_1'.
Status / Summary

你用的似乎是ADS2008或者2009吧。
按我的经验,在layout中将频率从0开始设置而不是只设要仿真的范围。

你是lookalike回去的吗?sch仿真时,你是不能改变端口频率范围。lookalike成功后有个对话框要提示这些内容的