用ADS瞬时仿真时出现error
录入:edatop.com 点击:
用ADS进行瞬时仿真时,出现下述的错误,这是我copy的仿真文件叙述
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X6218.L1.i' and `X5906.L1.i').
Error detected by HPEESOFSIM during DC analysis `Tran1'.
Circuit as given has no unique solution.
Warning detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X359.L1.i' and `X670.L1.i').
Error detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X540.L1.i' and `X982.L1.i').
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X737.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6334.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6314.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X344.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X5518.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X650.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X11290.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X635.L1.i.
Error detected by HPEESOFSIM during DC analysis `Tran1'.
No DC convergence.
To search for a more robust convergence algorithm,
set ConvMode=1 on the DC analysis and perform the DC
simulation again. This will cause the simulator to vary
the convergence parameters and report which parameter
setting produces the fastest convergence.
Status / Summary
HPEESOFSIM (*) 2003A.300 Apr 9 2003 (built: 04/09/03 22:50:55)
Copyright Agilent Technologies, 1989-2003.
.................
Perform Pseudo-Transient analysis
..
Error: Circuit Failes to converge at node `_net350649'
-------------------------------------------------------------------------------
Simulation finished with errors.
当中提到要把ConvMode=1,可是我没有找到在哪里设置这个参数
这个问题比较棘手,望达人赐教
多谢
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X6218.L1.i' and `X5906.L1.i').
Error detected by HPEESOFSIM during DC analysis `Tran1'.
Circuit as given has no unique solution.
Warning detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X359.L1.i' and `X670.L1.i').
Error detected by HPEESOFSIM during TRAN analysis `Tran1'.
Matrix is singular (detected between nodes or branches `X540.L1.i' and `X982.L1.i').
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X737.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6334.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X6314.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X344.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X5518.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X650.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X11290.L1.i.
Warning detected by HPEESOFSIM during DC analysis `Tran1'.
A virtual resistance of 1 pOhms
was added to branch X635.L1.i.
Error detected by HPEESOFSIM during DC analysis `Tran1'.
No DC convergence.
To search for a more robust convergence algorithm,
set ConvMode=1 on the DC analysis and perform the DC
simulation again. This will cause the simulator to vary
the convergence parameters and report which parameter
setting produces the fastest convergence.
Status / Summary
HPEESOFSIM (*) 2003A.300 Apr 9 2003 (built: 04/09/03 22:50:55)
Copyright Agilent Technologies, 1989-2003.
.................
Perform Pseudo-Transient analysis
..
Error: Circuit Failes to converge at node `_net350649'
-------------------------------------------------------------------------------
Simulation finished with errors.
当中提到要把ConvMode=1,可是我没有找到在哪里设置这个参数
这个问题比较棘手,望达人赐教
多谢
有没有人帮帮我阿……
.........................
无能为力
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:ARM embedded memory ip的产生,couldnt run spreadsheet generator to fetch results
下一篇:AD7799 等24位ADC 编程问题
ADS培训课程推荐详情>>
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集