• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > ADS > ADS FAQ > Convergence error in simulation with an EM model

Convergence error in simulation with an EM model

录入:edatop.com    点击:
Convergence errors occur in a simulation with an EM model in harmonic balance simulation.
But there is no convergence error in a simulation with electrical models(microstrip line models and so on) of ADS.
The error only occurs with its EM model extracted from its layout.
I read the document of convergence error in harmonic balance simulation in the manual of ADS.
I tried applying the techniques suggested in the document, such as changing the OSR, using TAHB, auto(preferred) convergence mode, advanced (robust) convergence mode, changing iterations to robust and custom with 1000, direct solver, Krylov solver, Matrix re-use robust, custom, Krylove Restart length (robust, low memory, custom), and so on...
I also tried changing some of advanced continuation parameters and advanced krylov parameters.
But still no success in convergence.
What could I try to reach the convergence?
Thank you very much.

Try to check the biasing of the non-linear device, quite often not a proper biasing leads to convergence issues.
Also you can check the small signal stability when running s-parameter simulation, since s-parameters should still run, and if it is not stable there - that would be the cause for convergence issue.

Hope that helps.
Regards

申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程