ADS Momentum: Port not snapped
I have just found some strange about placing port in Momentum layout. As seen from the picture, there are two ports where one port (blue) can snap to Metal 1 (blue), but the other port (orange) cannot snap to Metal 2 (orange). Not matter how large I zoomed to place the port to Metal 2, I could not make that port to snap to Metal 2. I tried to turn on every snap mode, but could not succeed. As seen, both Metal 1 and Metal 2 are on grid.
Anyone has seen this issue before ? As described from Momentum document, it says that even port is not snapped, it will snap automatically to the closest structure in the simulation, but not in the layout ...... Is this true ?
Thanks a lot :)
DYL
Yes, don't worry.
The blue port in your layout is snapped to a pin in the layout.
The red port in your layout is snapped to an edge where there is no pin in the layout.
Both cases are valid and work fine.
Dear Volker,
Thank you very much for your explanation. So, it means in Momentum that, even I could snap a pin to an edge of a layout, Momentum will snap that pin to the nearest edge in the simulation, right ?
DYL
Yes, you can snap the EM port to any layout edge using the snapping function, and Momentum will use that edge for the port. Everything is OK for your "red" port configuration.
Dear Vollker,
Thanks a lot for your confirmation again :)
DYL
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:Noise effects in a power source in ADS
下一篇:S21 Parameters Momentum Simulation on ADS
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集