- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
S to RLGC in ADS (S2RLGC in MATLAb)
录入:edatop.com 点击:
I have S-parametrs(S11,S12,S21,S22) for line in my topology - calculated in ADS "momentum",
how I can get out of them "RLGC line parameters" in ADS ?
(in MATLAB - "S2RLGC" function)
ADS have:
schematic->tools->spice model Generator-> Narrow Band Generator -> ***.S2P to Lumped PI-network model
generate file in spice
R1 1 0 10331.3540784334
C1 1 0 10.5060569186053PF
R2 2 0 10291.079076375
C2 2 0 9.01927637973095PF
R3 1 4 0.462253414198611
L1 4 2 47.2034669894539NH
good, cool.. in my case too simple.. since no frequency dependent parameters.. and at high frequencies(500 MHz) is not "true" model
Cadence Sigrity says that for frequencies from 400 MHz to 500 MHz capacity in RLGC model begins to rise and increases to 120pF (0.png and 3.png)
but this is not visible on the S-parameters (1.png and 2.png) in Sigrity
S-parametrs in Sigrity and in ADS are similar (1.png and 4.png)
I can calculate the impedance line knowing the load (Port2) through S11
but the 5.png does not look like the graph of Sigrity 3.png
I would like to find out capacity from RLGC model in ADS
because the experiment, shows that from 400MHz something goes wrong
please, help
how I can get out of them "RLGC line parameters" in ADS ?
(in MATLAB - "S2RLGC" function)
ADS have:
schematic->tools->spice model Generator-> Narrow Band Generator -> ***.S2P to Lumped PI-network model
generate file in spice
R1 1 0 10331.3540784334
C1 1 0 10.5060569186053PF
R2 2 0 10291.079076375
C2 2 0 9.01927637973095PF
R3 1 4 0.462253414198611
L1 4 2 47.2034669894539NH
good, cool.. in my case too simple.. since no frequency dependent parameters.. and at high frequencies(500 MHz) is not "true" model
Cadence Sigrity says that for frequencies from 400 MHz to 500 MHz capacity in RLGC model begins to rise and increases to 120pF (0.png and 3.png)
but this is not visible on the S-parameters (1.png and 2.png) in Sigrity
S-parametrs in Sigrity and in ADS are similar (1.png and 4.png)
I can calculate the impedance line knowing the load (Port2) through S11
but the 5.png does not look like the graph of Sigrity 3.png
I would like to find out capacity from RLGC model in ADS
because the experiment, shows that from 400MHz something goes wrong
please, help
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:ADS and S11 Equations for L & C
下一篇:How to use 4 s1p -file to create a user component for simulation in ADS
ADS培训课程推荐详情>>
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集