Difference between foundry model and ADS simulation result of inductor
To verify the validity of my ADS simulation method, I'd like to compare the foundry model(simulated in Cadence, 55nm GlobalFoundry)with ADS simulation results and see if they match.
The comparison involves S-parameters(S11,S21),inductor, and resistance. Now my problem is, S21 and resistance between the two are a bit far from identical.
Take the following case for example(please refer to Inductor.JPG), it's a differential inductor made of three top metal layers, the patterned ground shield is down under made in a lower metal(i.e. M1).
The comparison results are shown in Result_Comparison.JPG: it seems like the faster growth of parasitic resistance has caused a bigger insertion loss(i.e. S21), is that right?
In light of the difference, there are two settings I am really doubting about:
1)Substrate. Since I haven't found out the dielectric constants in the process document, I get these "average" values by calculation upon post-simulation capacitance extraction in plate capacitor model.Please refer to Substrate.JPG.Are there any apparent mistakes?
2)Ground connnection of patterned shield. I finish the ground connection by simply putting a pin over M1?s left edge and then connecting it to ground in the schematic view. I've found out the pin position can slightly affect the simulation results. Should there be any special handling on this?
Does the extracted inductance show reasonable agreement?
Your ADS model has less DC series resistance, but faster growth from skin effect and/or substrate losses. The expected DC resistance can be checked by manual calculation using process spec resistances for metal layers and vias. For high frequency response, you really need the correct substrate conductivity (and for more accurate results consider possible EPI layer with different conductivity).
For the patterned ground shield, connecting the shield to GND and evaluating the differential mode results is correct. You get differential mode results if you place a "floating" port and connect it between the two inductor terminals. ADS then uses a symmetric excitation for that port, so that you shield connected to ADS ground symbol is a mid potential, as desired.
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:Interleaved Transformer using Keysight ADS CoilSys
下一篇:Dissimilarity in FEM Results of Resonant Patch Antenna in HFSS and ADS
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集