defining ground plane in ads 2011 momentum setup
I ve been searching thru the similar threads, and I see that there is not a clear consensus on the way we can define the ports in momentum simulation setup for ads version 2011; (NOT the 2009 version).
My question -however it may sound silly- is as follows with the figure below:
In this figure the orange colored line is a thick top metal, 200 um long, 16 um wide... the blue outline is actually a metal 1 layer underneath the top metal... This Metal 1 will be connected to the ground using substrate contacts later in the system level. It is a simple microstrip line with Metal 1 ground... (my pin placement may be wrong, so pls feel free to comment on them as well)
Well, the substrate has a cover layer way below the metal 1 and it seems like the ads 2011 assigns the universal ground to that layer... (GND)
So, how can i override this GND assignment? How do I confine my analysis of this transmission line to these Topmetal and Metal 1 layers?
From my preliminary simulations, I ve noticed that the TML or None options inthe port setup have significant effects on the characteristics of this TLine (S11 has 20 dB difference in level for the two cases, and it seems that my TLine can oscillate on its own at 70 GHz! just by itself when I select TML calibration mode with all ports are referenced to GND individually... pls see the figure: the blue line is the TML options checked. The pink line is when you group two metal 1 ports and assign them to the negative terminals of port 1 and port 2 of the topmetal.)
I hope I ve made myself clear enough. If not, you can try out a similar structure and test it with various combinations and notice the differences...
So the question is where do I go wrong? and how do we set the alternate ground plane without modifying the substrate that comes with the PDKs.
thanks in advance
Hi,
I also have the same problem.
Please, help to understand how to ground the shield layer for microstrip line correctly.
Thanks in advance
Only if you have NOT assigned an explicit ground.
This is now very simple in ADS 2011. Let's say your signal line has pins 1 and 2, and the ground has pins 3 and 4. Open the EM Setup and you will see 4 pins. By default, every pin is mapped to a port.
But now, you can select pin 3 with the mouse, and drag it to the minus terminal of port 1. Same for the other ground pin. Now, you have two ports: one port with pin1(+) and pin3(-) and another port with pin2(+) and pin4(-).
I can not comment on the calibration issues, but maybe it is resolved by defining the ports properly.
Thanks volker,
As for the selection of "TML" or "None" options in that EM setup (port window):
once you set the ports as you've described above... and run the EM simulation, do you get any warning messages related to Calibration?
regards,
calp
It became more clearer.
Thanks a lot!
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集