- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
CPW simulation in ADS using momentum and co-sim
录入:edatop.com 点击:
Hi all, i found some discrepancies when simulating a CPW in ADS momentum compared to when co-simulating in ADS the same layout. Wonders if someone can help clarify things. It's a bit involved so I thank you so very much for your patience.
Situation:
We are simulating a coplanar waveguide (CPW)using momentum and
co-simulation. A CPW calculator
http://www.microwaves101.com/encyclopedia/calcpw.cfm gives the dimensions
for a 50 Ohm CPW to be:
ground plane to signal track spacing=0.12mm
track width=1 mm
for
dielectric constant=4.5
and track height of=1 mm
I've created a layout in momentum that incorporates these dimensions in the
attached project file.
Problem:
Using momentum (pic: CPW50) and using ground
reference ports (P3,4,5,6) and internal ports (P1,2, i need to use internal ports since a similar design will be incorporated into a more complex system where
components will be attached to the ports),
we got a flat, broadband S21 (pic:Mom_flat_S21). and if we keep this config for co-sims, we get a flat S21 and good eye diagram.
But when the GND reference ports are removed and substituted with internal
ports (all P1-P6 are internal ports)
and a co-simulation is done, (pic:coSIM_S21),
a non flat S21 is obtained, (pic:coSIM_S21_non_flat)
when an eye diagram simulation is done, (Pic:coSIM_eye), a closed
eye is obtained even though the impedances are matched,
(pic:coSIM_eye_result)
Request:
Can you please advice:
1. How to get a flat S21 in co-simulation mode like in the momentum only
mode using all internal ports?
2. Get an opened eye diagram in co-simulation with all the impedances
matched at 50 Ohm when all ports are internal ports?
Or is it not possible?
Thanks for your time and looking forward for your response
raebrm
Situation:
We are simulating a coplanar waveguide (CPW)using momentum and
co-simulation. A CPW calculator
http://www.microwaves101.com/encyclopedia/calcpw.cfm gives the dimensions
for a 50 Ohm CPW to be:
ground plane to signal track spacing=0.12mm
track width=1 mm
for
dielectric constant=4.5
and track height of=1 mm
I've created a layout in momentum that incorporates these dimensions in the
attached project file.
Problem:
Using momentum (pic: CPW50) and using ground
reference ports (P3,4,5,6) and internal ports (P1,2, i need to use internal ports since a similar design will be incorporated into a more complex system where
components will be attached to the ports),
we got a flat, broadband S21 (pic:Mom_flat_S21). and if we keep this config for co-sims, we get a flat S21 and good eye diagram.
But when the GND reference ports are removed and substituted with internal
ports (all P1-P6 are internal ports)
and a co-simulation is done, (pic:coSIM_S21),
a non flat S21 is obtained, (pic:coSIM_S21_non_flat)
when an eye diagram simulation is done, (Pic:coSIM_eye), a closed
eye is obtained even though the impedances are matched,
(pic:coSIM_eye_result)
Request:
Can you please advice:
1. How to get a flat S21 in co-simulation mode like in the momentum only
mode using all internal ports?
2. Get an opened eye diagram in co-simulation with all the impedances
matched at 50 Ohm when all ports are internal ports?
Or is it not possible?
Thanks for your time and looking forward for your response
raebrm
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:how to export S-matrix from ADS
下一篇:Power Combiner EM Simulation in ADS Momentum
ADS培训课程推荐详情>>
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集