- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
How to check different temperature values for design of LNA IN ADS.
录入:edatop.com 点击:
I wish to design Low Noise Amplifier in the Ku Band using Agilent ADS. How to check different temperature values for different bias values using Agilent ADS. What Settings we need to do, can you send regarding documents for setting values different temperature values for different biasing values of LNA.
For Temperature, you have to place "Options" block and temp variable can be set in it..
In order to sweep any biasing value, you should use "Parameter Sweep" block ..
But first things first, you should read ADS Help and associated docs...
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:s parameters from simulation not as same as s parameters from datasheet BY ADS
下一篇:ATF-34143 ADS model to S2P file S parameter comparison in ADS