ads noise figure
I am doing LNA noise figure simulation in ADS using sp simulator. Then I choose option to try to add noise in. but when I try to "select input port" to term 1, software reports *Warning* object selected is not a valid selection object. So I am wondering if I need to use some other ports to do it? I also tried to give the port number in "select input port" , then it works but I am not sure if it correct. Can anyone comfirm this by giving some offical link? Also, what is different between nf1 and nf2. It looks to me nf2 is a more reasonble nf.
Thanks a lot for your help.
don't specify any port , and plot the Nf(2), this is the input refereed noise figure when port 2 is the output
khouly
Yes, it seems to be the right way, but what's does the NF(1) refer to?
Thanks
as far as i know , it is the opposite of nf(2)
khouly
what does it mean? Opposite?
May be NF1 is noise figure at port 1(input port) & noise figure at port 2 i.e output posrt is NF2.
please confirm
I did not think so since NF1 is incredible high!
Alright, NF1 means the noise figure at port1 when port 2 is input. Similar to the meaning of NF2, the noise figure at port 2 when port 1 is input.
Game king is correct,
S12 will be low and hence you will get NF1 incredible high in LNA.
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:problem in plotting MOSFET I-V curve in ADS software
下一篇:how does agilent ads calculate phase noise
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集