Hi all,

I am trying to simulate a transmission line. I have a set for RLGC data (at some frequency points) and want to use this data in a transmission line. How can I do this in ADS ? In Cadence, I can select "RLGC model" in "mtline" component. I don't know how to do the same thing in ADS. Please suggest .....

Thank you in advance,

DYL

Hi!

Yea, it seems not straightforward. "Google for RLCG file" . It seems some component data can be entered through a file which can be included. If its one frequency, you might just draw it with RLCG components (20 repititions per wavelength)

Good luck

Hi Darkcrusher,

Thank you for your answer. It seems that I need to use TLine_Multilayer to operate with RLGC file in ADS.

DYL

Use W-Element as HSPICE compatibility ability of Agilent ADSsim.
W_Element (Multi-Conductor Transmission Lines) - ADS 2009 - Agilent EEsof Documentation Center
Compatible Features and Limitations - ADS 2009 - Agilent EEsof Documentation Center

Hi pancho_hideboo,

Thank you very much for the information. However, as I searched from internet, I could not find how to define RLGCfile (static, tabular_list, tabular_file) to be used with the W_Element in ADS. I just have a set of RLGC data extracted from an EM simulator (the format is: freq, R, L, G, C). I don't know that how should I re-arrange the RLGC data I have to be compatible with those ADS need.

Thank you very much in advance,

DYL

It seems you don't know other simulators than Cadence Spectre and Agilent ADSsim.

See "HSPICE Signal Integrity User Guide".
http://www.ece.rochester.edu/courses.../hspice_si.pdf

"W-element of HSPICE" is a defacto standard transmission line model for SPICE type Transient simulator.

"analogLib/mtline for Cadence Spectre" is no more than an imitation of HSPICE W-element.
Actually "analogLib/mtline for Cadence Spectre" has been developed for aiming at HSPICE W-element.
So setting parameters of "analogLib/mtline for Cadence Spectre" very resemble them for HSPICE W-element.

Both Agilent ADSsim and GoldenGate understand Cadence Spectre Netlist directly,
but they don't support "analogLib/mtline for Cadence Spectre".

The Designer's Guide Community Forum - Index is almost Cadence Tool Support Forum,
so you can never expect any helpful reply other than Cadence Tool there.
The Designer's Guide Community Forum - Is it possible to enter RLGC data of a transmission line in ADS ?

Thank you very much, pancho_hideboo,

I am studying about the information you gave to me.

DYL

申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程