• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > ADS > ADS FAQ > Have this circuit in ADS and i want to calculate IIP3

Have this circuit in ADS and i want to calculate IIP3

录入:edatop.com    点击:
i have this circuit in ADS and i want to calculate IIP3 .
can anybody help me?

See http://edocs.soco.agilent.com/displa...er+Simulations

Use HB1ss or HB2 analysis.

Also see http://www.designers-guide.org/Forum...num=1262828862

it didn't help me...

Why ?

My links are very enough for evaluation of IIP3 for your simple differential amplifier.

What is your question ?

First of all, there is no signal source driving your differential amplifier.
Do you understand a definition of IIP3 ?

yes i know!

let me see your secound link..

PS:
oh no
the secound link did not help me too
please explain the method for me

If you know a definition of IIP3 for your circuits correctly, I think you don't have to post question at all.

Again my links are very enough for evaluation of IIP3 for your simple differential amplifier.

What on earth is your question ?

Again see links I refered surely.
Especially, second link is not easy to understand unless you are very familiar with both Agilent ADS and Cadence Spectre.

i don't want you to refer me to Advanced Design System 2009 guide page...

i just want a simple hint!

Your requirement of simulation is too easy.
So there is no simple hint better than "Tutorial Examples in Advanced Design System 2009".
See "Tutorial Examples in Advanced Design System 2009" surely.

And followings are not from "Tutorial Examples in Advanced Design System 2009".
http://www.designers-guide.org/Forum...62828862/20#20
http://www.designers-guide.org/Forum...62828862/22#21

As far as I see all your previous posts, you also have Cadence Spectre although you don't seem to be familiar with Cadence Spectre too.

If you use Cadence Spectre instead of Agilent ADS, can you do simulation setup of IIP3 ?
If so, IIP3 evaluation in ADS is same conceptually.

Or is there any simulation enviornment where you can do IIP3 evaluation, such as Mentor eldoRF, Synpopsys HSPICE-RF, etc.
Again, IIP3 evaluation in ADS is same conceptually whatever simulator you use.

If you have actual measurement experience of IIP3, simply emulate actual measurement setup in simulation.

Learn measurements using actual instruments. Not "EDA Tool Play".

you know, i can measure IIP3 using HSPICE, but in HB simulation in ADS there is an IP3in tool and i want to use this tool.

It is very suspicious whether you can measure IIP3 correctly using HSPICE.

It seems you can't understand IIP3 evaluation for your circuits at all.

"iip3_in()" returns value as "dBm".

http://edocs.soco.agilent.com/displa...%28%29-1105339

Simply do same measurement as HSPICE by using ADS HB analysis.

Generally IIP3 is defined for input voltage not input power for your simple circuit.
So IIP3 is evaluated for relation of differential output voltage v.s. differential input voltage.

Do you define IIP3 as input power with some reference impedance value ?

It seems you can't understand IIP3 evaluation for your circuits at all.

"iip3_in()" return as "dBm".

http://edocs.soco.agilent.com/displa...%28%29-1105339

Simply same measurement using ADS HB analysis as HSPICE.



i dont want you to help me
dont buzzer me Mr.
understand?

PS:
sorry!
sorry!

i think i must use Vn-tone and sweep the voltage amplitude

申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程

上一篇:How to simulate 16-port network in ADS
下一篇:a question in ADS optimization.

ADS培训课程推荐详情>>
Agilent ADS 栏目
频道总排行

  网站地图