If I do on wafer measurement with Cascade and HP8510C vector network analyzer (1-port measurement), and I only have S11 data from S parameter, how am I going to get Z parameter or Y parameter from S11 only?
Can anybody kindly help me, please? Thanks.
Dear,
Check Attached PDF File.This is an application note from HP(Agilent) about
S-Parameters that contains formulas & Relationship between S-Param with
Z,Y & H Params.
Good Luck!
Can you please convert the file into other format since i cannot open .rar files. Or how can I open it? Anyway, thanks for your help.
Dear,
Same file in zip format. for openning you can use winzip or winrar( trial versions)
(winrar : zip & rar,winzip :only zip) zip files also opened without any utility with
WinXP.
note : You can Also use FREE 7-ZIP from www.7-zip.org to open Zip and Rar Files.
it is also available for Various OS ( Windows,Linux,...)
The main features of 7-Zip:
High compression ratio in new 7z format with LZMA compression
7-Zip is free software distributed under the GNU LGPL
Supported formats:
Packing / unpacking: 7z, ZIP, GZIP, BZIP2 and TAR
Unpacking only: RAR, CAB, ISO, ARJ, LZH, CHM, Z, CPIO, RPM, DEB and NSIS
Good Luck!
You are being a little sloppy with your terminology, and it is getting you into big trouble.
You did not measure S11 on your one port device. You measured the reflection coefficient. To measure "S11" you needed to start with a 2 port device, and to put a 50 ohm load on the unused port. Clearly, you just measured the reflection coefficient (which is load independent, as there is no port to add a load to).
Similarly, you can not convert a reflection coefficient into Z11, since such a Z matrix assumes a two port device again. Z11 would be the impedance of port 1 with port 2 set so I2=0.
What you CAN do is to convert reflection coefficient data on a 1 port into impedance data for that 1 port.
Assuming you did your measurement on a 50 ohm network analyzer, then the complex impedance of the device is:
Z = 50 * [(1+ρ)/(1-ρ)] where ρ is the reflection coefficient. (ρ is, of course, a complex number).
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
上一篇:Problem with ADS design of an equal split wilkinson power divider at 960 MHz
下一篇:Linearity Simulation Problem in ADS
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集