ADS仿真噪声系数时遇到个问题
录入:edatop.com 点击:
Warning detected by hpeesofsim during SP analysis `SP1'.
The simulation temperature (25.0 C) is not the same as the IEEE standardnoise temperature (290 K or 16.85 C) in the noise analysis `SP1'.
If the simulation temperature is not equal to the IEEE standard temperature,then the loss and the noise figure will not agree for a passive circuit.
The `Temp' parameter on the Options item can be set to 16.85 C toeliminate this warning message.
请问这个仿真温度怎么设置啊?
The simulation temperature (25.0 C) is not the same as the IEEE standardnoise temperature (290 K or 16.85 C) in the noise analysis `SP1'.
If the simulation temperature is not equal to the IEEE standard temperature,then the loss and the noise figure will not agree for a passive circuit.
The `Temp' parameter on the Options item can be set to 16.85 C toeliminate this warning message.
请问这个仿真温度怎么设置啊?
添加一个叫做options的元件,在里面将仿真温度设定为16.85 摄氏度。
这个元件在任何一个仿真的元件库中都有
谢谢