- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
ADS layout生成器件后引入到电路仿真报错,求助
重贴一下报错内容:
Simulation / Synthesis Messages
Warning detected by hpeesofsim in topology check during circuit set up.
Number of nodes with only one device attached (topology corrected): 5
Number of nodes with no DC path to ground (topology corrected): 19
Error detected by hpeesofsim during TRAN analysis 'SP1'.
`test_1': S-parameters are not available at 0 Hz.
Error detected by hpeesofsim during TRAN analysis 'SP1'.
Fatal error occurred while evaluating model `MomCmpt', instance `test_1'.
Status / Summary
hpeesofsim (*) 331.200 May6 2008 (built: 05/06/08 00:26:15)
Copyright Agilent Technologies, 1989-2008.
******************************************
***** Abnormal Simulator Termination *****
******************************************
The simulator has unexpectedly terminated.
可能是你在layout下的频率设置和schematic下的不同。
频率设成一直也不管用啊,那位高手帮忙解答胰一下怎么化解啊?
Simulation / Synthesis Messages
Warning detected by hpeesofsim in topology check during circuit set up.
Number of nodes with only one device attached (topology corrected): 10
Error detected by hpeesofsim during SP analysis 'SP1'.
`X090224_output_1': Syntax error in the Layout Component ModelDatabase citi-file.
Error detected by hpeesofsim during SP analysis 'SP1'.
Fatal error occurred while evaluating model `MomCmpt', instance `X090224_output_1'.
Status / Summary
你用的似乎是ADS2008或者2009吧。
按我的经验,在layout中将频率从0开始设置而不是只设要仿真的范围。
你是lookalike回去的吗?sch仿真时,你是不能改变端口频率范围。lookalike成功后有个对话框要提示这些内容的
申明:网友回复良莠不齐,仅供参考。如需专业帮助,请学习易迪拓培训专家讲授的ADS视频培训课程。
国内最全面、最专业的Agilent ADS培训课程,可以帮助您从零开始,全面系统学习ADS设计应用【More..】
- Agilent ADS教学培训课程套装
- 两周学会ADS2011、ADS2013视频教程
- ADS2012、ADS2013射频电路设计详解
- ADS高低阻抗线微带滤波器设计培训教程
- ADS混频器仿真分析实例视频培训课程
- ADS Momentum电磁仿真设计视频课程
- ADS射频电路与通信系统设计高级培训
- ADS Layout和电磁仿真设计培训视频
- ADS Workspace and Simulators Training Course
- ADS Circuit Simulation Training Course
- ADS Layout and EM Simulation Training Course
- Agilent ADS 内部原版培训教材合集