- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
awr emsight tutorial
Thanks
Lanny
PS: Is there any EMSight in depth tutorial around here? I just have take a brief look at AWR website for any EMSight tutorial but found only few examples.
Hello Lanny,
Just edit the STACKUP block properties in the Global Definations page...
Such as Dielectric layers, Conductor material, EM mappings it works fine...
I have atttached all the corresponding screen shot pictures with results for you...
If you stiall want the project file let me know....!
---manju--
Manju,
You're the man. Thanks for your help. No need for the project file because I can handle it from here.
I've a question for you. I've changed the perfect conductor to 0 mil and Trace1 to 0.7 mils in material to fit my work. I also changed EM Layer Mapping of Via & Copper to Trace 1. Why after simulating, the enclosure property of Via & Copper changed back to perfect condition? Just a curious question because I don't have any error message, and everything is working.
Never mind Manju, I found the root of my problem.
My problem is the EMSight enclosure is a simulation copy version of my STACKUP and it can be edited as if you are editing the STACKUP. So I thought I have edited my STACKUP but in reality, I was editing the EM Structure's enclosure and the STACKUP is never edited and corrected. No wonder my problems keep showing up the same and I've keep saying I've thought I just fixed that.
What a stupid problem I have.