- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
Import .sNp to Microwave Office - Limit on N ports?
However, when I had a larger .sNp file (18 ports) I was not able to import it. It did not even show up in the browser when looking for the files.
Is there a limit to the number of ports in these S-parameter files?
Thanks,
~Nick
Hello Nick,
The touchstone file format for S-parameters has no limitation on number of ports (it supports upto 99 ports)
only your data HEADER format shout match
If the data is real/imaginary and the frequency unit is GHz, the header line is this:
# GHZ S RI R 50.00
If the data is in magnitude dB and phase format, the header line is this:
# GHZ S DB R 50.00
So AWR Microwave Office (MWO) supports above format...
If you still have problems then upload your *.S18P file here....
AWR Microwave Office 培训课程套装,视频教学,帮助您快速学习掌握MWO...
上一篇:documentation related to noise of RF switch and an AWR simulation
下一篇:PLL synthesizer using AWR microwave office question