• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > HFSS > HFSS help > Modifying SAR Settings

HFSS15: Modifying SAR Settings

录入:edatop.com     点击:

HFSS uses default specific absorption rate (SAR) settings when creating a local SAR or average SAR field overlay plot. It does use mass density for each material if defined for each material. Otherwise (that is, if the mass density for that library material is 0), the density in the Specific Absorbtion Rate Setting dialog will be used. To change the default settings:

1. Click HFSS>Fields>SAR Setting.

The Specific Absorption Rate Setting dialog box appears.

2. In the Material Density text box, enter the mass density of the dielectric material in g/cm3.

3. In the Mass of Tissue text box, enter the mass of the material that surrounds each mesh point. This can be a value between 1 and 10.

4. Click OK.

HFSS 学习培训课程套装,专家讲解,视频教学,帮助您全面系统地学习掌握HFSS

上一篇:Modifying Field Plot Colors
下一篇:Modes to Terminals Conversion

HFSS视频培训课程推荐详情>>
HFSS教程推荐

  网站地图