HFSS15: Saving Field Solutions for a Tuning Analysis
In order to preserve disk space, by default HFSS does not save field solution data for every design variation solved in a tuning analysis. It only saves the field solutions for the nominal design when an adaptive analysis is specified in the solution setup or when you request that fields be saved for each solved point in a frequency sweep. If the nominal design is not included in the tuning analysis, all field solutions are deleted.
To save the fields for all design variations solved during a tuning analysis:
In the Tuning dialog box, select Save Fields.
HFSS will save the field solution data for every solved design variation in a tuning analysis.
HFSS 学习培训课程套装,专家讲解,视频教学,帮助您全面系统地学习掌握HFSS
上一篇:Save Before Solve Option
下一篇:Saved Fields Tab for Transient Solution Setup