- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
HFSS15: Specifying a Single Goal Value
Specifying a Single Goal Value
1. Under the Goals tab in the Setup Optimization dialog box, click Edit Goal/Weight.
The Edit Goal/Weight dialog box appears.
2. Under the Goal Value tab, click Simple Numeric Value from the Type list.
3. If the goal value is complex, click real/imag in the pull-down list to the right if you want to specify the real and imaginary parts of the goal value.
Alternatively, click mag/ang if you want to specify the magnitude and angle of the goal value.
4. Type the goal value in the Goal Value table.
If the goal value is complex, type both parts of the goal value in the text box below the Goal Value heading. For example, type 1, 1 to specify the real part of the goal value as 1 and the imaginary part as 1.
If the goal value is real, type a real goal value in the text box below the Goal Value heading.
5. Click OK.
The goal value you specified appears in the Goal text box.
HFSS 学习培训课程套装,专家讲解,视频教学,帮助您全面系统地学习掌握HFSS
上一篇:Solving a Parametric Setup During a Statistical Analysis
下一篇:Specifying Initial Mesh Settings