Solving a parametric setup during a sensitivity analysis is useful when you want Optimetrics to solve every design variation in the parametric setup at each sensitivity analysis iteration. An output parameter goal could then depend on the value of the variable swept in the parametric setup.

To solve a parametric setup during a sensitivity analysis:

1. In the Setup Sensitivity Analysis dialog box, click the General tab.

2. Click the parametric setup you want Optimetrics to solve during the sensitivity analysis from the Parametric Analysis pull-down list.

3. Select Solve the parametric sweep during analysis.