The value you set for percent Maximum Refinement Per Pass determines how many tetrahedra are added at each iteration of the adaptive refinement process. The tetrahedra with the highest error will be refined. The default value is 30%.

To set the percent refinement per adaptive pass:

• Under the Options tab of the Solution Setup dialog box, enter a value for percent Maximum Refinement Per Pass.