- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
diffrent results in hfss feko and cst
录入:edatop.com 点击:
Hi,
Hope everybody are good.
Please find attached full question with diagrams.Question.pdfQuestion.pdf
A coax-fed patch antenna with dimensions given in table below, is simulated in HFSS, CST and FEKO
softwares.
It is seen that:
The results of the CST software in the case of
- The phase Z component of the electric field on the line parallel to y axis
and
The results of the FEKO software in the case of
- The magnitude of X component of the electric field on the line parallel to y axis
- The phase of X component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to x axis
and
The results of the HFSS software in the case of
- The phase of X component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to y axis
are completely different from the results of the two other softwares (despite partial similarity of the field
behavior in other cases).
The question is why it is such different.
Hope everybody are good.
Please find attached full question with diagrams.Question.pdfQuestion.pdf
A coax-fed patch antenna with dimensions given in table below, is simulated in HFSS, CST and FEKO
softwares.
It is seen that:
The results of the CST software in the case of
- The phase Z component of the electric field on the line parallel to y axis
and
The results of the FEKO software in the case of
- The magnitude of X component of the electric field on the line parallel to y axis
- The phase of X component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to x axis
and
The results of the HFSS software in the case of
- The phase of X component of the electric field on the line parallel to y axis
- The phase of Z component of the electric field on the line parallel to y axis
are completely different from the results of the two other softwares (despite partial similarity of the field
behavior in other cases).
The question is why it is such different.
Have you checked local mesh density in the area where you sample the fields?
Thank you for your reply.
yes we checked that and also we checked for different meshes and we got same results again.
Ok.
To me, the spikes in the fields looked like an artefact from insuffient mesh density in the probed region.
CST微波工作室培训课程套装,专家讲解,视频教学,帮助您快速学习掌握CST设计应用
上一篇:warning 1663 feko
下一篇:printed dipole feko