- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
新人求教
录入:edatop.com 点击:
本人刚学着用Protel绘图,遇到一个问题,怎么也不知道错误出在哪?请教老师
P0口使用网络编号的方法连了8个LED
各个元器件封装设置好,电气规则检查也没出现错误
生成PCB时,错误报告如下
Protel Synchronization report
=========================================================================
Date : 18-Jan-2013
Time : 17:28:39
Reference document: Sheet1.Sch
Target document: 51board.PCB
=========================================================================
ERRORS: 16 macros can not be executed:
-------------------------------------------------------------------------
Macro 1: New Node
Add node LED1-A to net NetLED1_A
Error: Node not found
Macro 2: New Node
Add node LED7-A to net NetLED1_A
Error: Node not found
Macro 3: New Node
Add node LED8-A to net NetLED1_A
Error: Node not found
Macro 4: New Node
Add node LED6-A to net NetLED1_A
Error: Node not found
Macro 5: New Node
Add node LED5-A to net NetLED1_A
Error: Node not found
Macro 6: New Node
Add node LED4-A to net NetLED1_A
Error: Node not found
Macro 7: New Node
Add node LED3-A to net NetLED1_A
Error: Node not found
Macro 8: New Node
Add node LED2-A to net NetLED1_A
Error: Node not found
Macro 9: New Node
Add node LED8-K to net DB7
Error: Node not found
Macro 10: New Node
Add node LED7-K to net DB6
Error: Node not found
Macro 11: New Node
Add node LED6-K to net DB5
Error: Node not found
Macro 12: New Node
Add node LED5-K to net DB4
Error: Node not found
Macro 13: New Node
Add node LED4-K to net DB3
Error: Node not found
Macro 14: New Node
Add node LED3-K to net DB2
Error: Node not found
Macro 15: New Node
Add node LED2-K to net DB1
Error: Node not found
Macro 16: New Node
Add node LED1-K to net DB0
Error: Node not found
请教一下这是什么原因,请高手回帖或者加QQ707825472给我帮助
顺便问一下,有没有好的PROTEL交流群,能加我进一下群
好人一生平安!
P0口使用网络编号的方法连了8个LED
各个元器件封装设置好,电气规则检查也没出现错误
生成PCB时,错误报告如下
Protel Synchronization report
=========================================================================
Date : 18-Jan-2013
Time : 17:28:39
Reference document: Sheet1.Sch
Target document: 51board.PCB
=========================================================================
ERRORS: 16 macros can not be executed:
-------------------------------------------------------------------------
Macro 1: New Node
Add node LED1-A to net NetLED1_A
Error: Node not found
Macro 2: New Node
Add node LED7-A to net NetLED1_A
Error: Node not found
Macro 3: New Node
Add node LED8-A to net NetLED1_A
Error: Node not found
Macro 4: New Node
Add node LED6-A to net NetLED1_A
Error: Node not found
Macro 5: New Node
Add node LED5-A to net NetLED1_A
Error: Node not found
Macro 6: New Node
Add node LED4-A to net NetLED1_A
Error: Node not found
Macro 7: New Node
Add node LED3-A to net NetLED1_A
Error: Node not found
Macro 8: New Node
Add node LED2-A to net NetLED1_A
Error: Node not found
Macro 9: New Node
Add node LED8-K to net DB7
Error: Node not found
Macro 10: New Node
Add node LED7-K to net DB6
Error: Node not found
Macro 11: New Node
Add node LED6-K to net DB5
Error: Node not found
Macro 12: New Node
Add node LED5-K to net DB4
Error: Node not found
Macro 13: New Node
Add node LED4-K to net DB3
Error: Node not found
Macro 14: New Node
Add node LED3-K to net DB2
Error: Node not found
Macro 15: New Node
Add node LED2-K to net DB1
Error: Node not found
Macro 16: New Node
Add node LED1-K to net DB0
Error: Node not found
请教一下这是什么原因,请高手回帖或者加QQ707825472给我帮助
顺便问一下,有没有好的PROTEL交流群,能加我进一下群
好人一生平安!
建议这类简单问题最好直接上传 原始文档上来....
是你的LED的封装管脚好与原理图元件的管脚号码对不上
你原理图LED管脚的number用的是A、K,但是你LED的封装的管脚号码用的不是A、K,你可能用的是1、2
Add node LED6-A to net NetLED1_A
Error: Node not found
这个的意思就是LED6的A管脚找不到
小编去修改一下PCB封装库中的LED的封装,把管脚号码改的和原理图元件管脚号码一样就可以了
也可以去原理图库中改
这个问题在新人学PROTEL的时候都有遇到过,LZ加油 不会的再问
至于QQ群,你在这里发帖询问就可以了
谢谢
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:《2012年度中国1-2线城市外资电子电气工程行业薪酬福利报告》之高级软件工程师