• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > 电子设计 > PCB设计 > Orcad技术问题 > OrCAD网表导入PCB Editor有告警

OrCAD网表导入PCB Editor有告警

录入:edatop.com     点击:

(---------------------------------------------------------------------)(                                                                     )
(    Allegro Netrev Import Logic                                      )
(                                                                     )
(    Drawing          : 123.brd                                       )
(    Software Version : 16.6P004                                      )
(    Date/Time        : Sun Mar 22 16:16:02 2015                      )
(                                                                     )
(---------------------------------------------------------------------)
------ Directives
------RIPUP_ETCH FALSE;
RIPUP_DELETE_FIRST_SEGMENT FALSE;
RIPUP_RETAIN_BONDWIRE FALSE;RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;SCHEMATIC_DIRECTORY 'D:/AppData/OrCAD/palm_pspice/allegro';BOARD_DIRECTORY '';
OLD_BOARD_NAME '123.brd';NEW_BOARD_NAME '123.brd';
CmdLine: netrev -$ -i D:/AppData/OrCAD/palm_pspice/allegro -y 1 D:/AppData/OrCAD/palm_pspice/PSPice_example/example1/
#Taaaaat03092.tmp
------ Preparing to read pst files ------
Starting to read D:/AppData/OrCAD/palm_pspice/allegro/pstchip.dat   
Finished reading D:/AppData/OrCAD/palm_pspice/allegro/pstchip.dat
(00:00:00.03)
Starting to read D:/AppData/OrCAD/palm_pspice/allegro/pstxprt.dat   
Finished reading D:/AppData/OrCAD/palm_pspice/allegro/pstxprt.dat
(00:00:00.00)Starting to read D:/AppData/OrCAD/palm_pspice/allegro/pstxnet.dat   
Finished reading D:/AppData/OrCAD/palm_pspice/allegro/pstxnet.dat
(00:00:00.00)------ Oversights/Warnings/Errors ------#1   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]WARNING(SPMHNI-194): Symbol 'C0805' for device 'C_C0805_1N' not found in PSMPATH or must be "dbdoctor"ed.
#2   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]WARNING(SPMHNI-194): Symbol 'HEADER2' for device 'CON2_HEADER2_CON2' not found in PSMPATH or must be "dbdoctor"ed.
#3   WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_1K' not found in PSMPATH or must be "dbdoctor"ed.------ Library Paths ------MODULEPATH =  .            C:/Cadence/SPB_16.6/share/local/pcb/modules PSMPATH =  .            symbols            ..            ../symbols            C:/Cadence/SPB_16.6/share/local/pcb/symbols            C:/Cadence/SPB_16.6/share/pcb/pcb_lib/symbols            C:/Cadence/SPB_16.6/share/pcb/allegrolib/symbols PADPATH =  .            symbols            ..            ../symbols            C:/Cadence/SPB_16.6/share/local/pcb/padstacks            C:/Cadence/SPB_16.6/share/pcb/pcb_lib/symbols            C:/Cadence/SPB_16.6/share/pcb/allegrolib/symbols ------ Summary Statistics ------netrev run on Mar 22 16:16:02 2015   DESIGN NAME : 'WHAT'   PACKAGING ON Sep 10 2012 04:46:09   COMPILE 'logic'   CHECK_PIN_NAMES OFF   CROSS_REFERENCE OFF   FEEDBACK OFF   INCREMENTAL OFF   INTERFACE_TYPE PHYSICAL   MAX_ERRORS 500   MERGE_MINIMUM 5   NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'   NET_NAME_LENGTH 24   OVERSIGHTS ON   REPLACE_CHECK OFF   SINGLE_NODE_NETS ON   SPLIT_MINIMUM 0   SUPPRESS   20   WARNINGS ON No error detected No oversight detected  3 warnings detectedcpu time      0:00:24elapsed time  0:00:00SPMHNI-192:
This is a general warning that is normally paired with another message. Check the secondary message for more detail.
SPMHNI-192:
This is a general warning that is normally paired with another message. Check the secondary message for more detail.
SPMHNI-192:



同问

PCB封装库中无C0805、HEADER2、R0805对应的封装。