- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
新手请教allegro 导入网络 ,警告信息是否可忽略?
录入:edatop.com 点击:
我是新手,请教各位以下错误报表是我导入网络出现的提示,请问#1 WARNING(301) Device library warning detected.
这样的警告信息是不是可以忽略,ERROR 的错误信息是不可以忽略的?另外ERROR(302) Device library error detected,的错误信息是因为什么原因造成的,怎么解决?
------ Preparing to read pst files ------
Starting to read C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstchip.dat
Finished reading C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstchip.dat (00:00:00.39)
Starting to read C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstxprt.dat
Finished reading C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstxprt.dat (00:00:00.12)
Starting to read C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstxnet.dat
Finished reading C:/Documents and Settings/Administrator/桌面/练习/coby/allegro/pstxnet.dat (00:00:00.15)
------ Oversights/Warnings/Errors ------
#1 WARNING(301) Device library warning detected.
WARNING: U27 component device pin number mismatch; cannot replace.
#2 WARNING(301) Device library warning detected.
WARNING: SW7 component device pin number mismatch; cannot replace.
#3 WARNING(301) Device library warning detected.
WARNING: SW12 component device pin number mismatch; cannot replace.
#4 WARNING(301) Device library warning detected.
WARNING: SW11 component device pin number mismatch; cannot replace.
#5 WARNING(301) Device library warning detected.
WARNING: JC5 component device pin number mismatch; cannot replace.
#6 WARNING(301) Device library warning detected.
WARNING: JC1 component device pin number mismatch; cannot replace.
#1 ERROR(302) Device library error detected.
Device problem 'CAP NP_C0805_10UF/10V_1'. Package property error: 'VALUE'='10uF/10V'. Illegal character(s) present in name or value..
Device 'CAP NP_C0805_10UF/10V_1' has library errors. Unable to transfer to Allegro.
#2 ERROR(302) Device library error detected.
Device problem 'CAP NP_C0402_0.1UF_1'. Package property error: 'VALUE'='0.1uF'. Illegal character(s) present in name or value..
Device 'CAP NP_C0402_0.1UF_1' has library errors. Unable to transfer to Allegro.
#3 ERROR(302) Device library error detected.
Device problem 'CAP NP_C0402_0.1UF/16V_1'. Package property error: 'VALUE'='0.1uF/16V'. Illegal character(s) present in name or value..
Device 'CAP NP_C0402_0.1UF/16V_1' has library errors. Unable to transfer to Allegro.
------ Summary Statistics ------
#4 ERROR(102) Run stopped because errors were detected
netrev run on May 30 15:39:34 2011
DESIGN NAME : 'MID7019_256M_2G_RUSSELL_110429 0900'
PACKAGING ON May 28 2006 22:05:31
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
4 errors detected
No oversight detected
6 warnings detected
cpu time 0:06:25
elapsed time 0:00:02
封装有问题
呵呵,下面都报错误信息了,还警告?
netlist导入到pcb中时,最好确保完全正确,no error, no warning,否则到后面就是一大堆问题
不单单是警告,有4个错误!
1.文件夹最好不要用中文名;
2.你的封装名称存在小数点,空格,“/”等非法字符,所以报错。
封装名不能有小数点
警告最好是沒有.
回复 youxiar 的帖子
谢谢你,我看资料的时候有提到不能用中文名的路径,查封装用的是C0805,可能是VALUE 用了带/的符号,我再查查,第一次导网络,还得多研究研究,
回复 biglin 的帖子
警告真的不能有,实在没折把所有的警告都改正,就不会出错了,原来用的PADS,警告可忽略,初学ALLEGRO 还得多摸索呢
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:新人问个问题
下一篇:出图遇到问题 求助高手