- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
(已解决)网络表怎么看?(导入网络表出错,是什么原因)(求助)
录入:edatop.com 点击:
这样的一个网络表,我们应该注意哪块?我个人感觉
Cadence Design Systems, Inc. netrev 16.2 Thu Jun 30 09:25:40 2011
(C) Copyright 2002 Cadence Design Systems, Inc.
------ Directives ------————————————这个是不是就是一些信息类的,是不是可以不看?(1)
RIPUP_ETCH FALSE;
RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;
SCHEMATIC_DIRECTORY 'E:/WORK/飞尚气体检测项目/甲烷气体监测/硬件原理图及PCB';
BOARD_DIRECTORY '';
OLD_BOARD_NAME 'E:/Gongzuo/cadence/FAS_PCB_library/Pcb_lib(new)/text/demo_brd.brd';
NEW_BOARD_NAME 'E:/Gongzuo/cadence/FAS_PCB_library/Pcb_lib(new)/text/demo_brd.brd';
CmdLine: netrev -$ -i E:/WORK/飞尚气体检测项目/甲烷气体监测/硬件原理图及PCB -y 1 E:/Gongzuo/cadence/FAS_PCB_library/Pcb_lib(new)/text/#Taaaaaa02400.tmp
------ Preparing to read pst files ------——————————这个部分是不是专门来看错误的地方吧(2)
#1 ERROR(24) File not found
Packager files not found
#2 ERROR(102) Run stopped because errors were detected——————————是不是就看这两个就可以啊?(3)
netrev run on Jun 30 9:25:40 2011
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
2 errors detected
No oversight detected
No warning detected
cpu time 0:00:29
elapsed time 0:00:00
哪位高手知道这个错误是什么原因造成的?不吝赐教,不胜感激!
找不到你的零件,你的零件库链接有问题。
是不是PCB 里面设置的 库、焊盘路径没搞对,还是你库和焊盘都没
楼上说的对,还有是不是可能你的封装是老版本的,先打开保存为新版本的才能使用。
问题找到了,是生成网络表的时候,保存的路径有汉字,最后复制到C盘下运行,就通过了
希望入门的同志不要犯这么低级的错误啊!
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:16.5找不到破解文件