• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > 电子设计 > PCB设计 > Allegro PCB技术问答 > 求助 网表导入问题

求助 网表导入问题

录入:edatop.com     点击:
(---------------------------------------------------------------------)
(                                                                     )
(    Allegro Netrev Import Logic                                      )
(                                                                     )
(    Drawing          : 112.brd                                       )
(    Software Version : 16.3S026                                      )
(    Date/Time        : Sat Sep 26 22:31:00 2009                      )
(                                                                     )
(---------------------------------------------------------------------)

------ Directives ------
RIPUP_ETCH FALSE;
RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;
SCHEMATIC_DIRECTORY 'F:/cundang/allegro';
BOARD_DIRECTORY '';
OLD_BOARD_NAME '112.brd';
NEW_BOARD_NAME '112.brd';
CmdLine: netrev -$ -i F:/cundang/allegro -y 1 F:/cundang/#Taaaaaa03952.tmp
------ Preparing to read pst files ------
Starting to read F:/cundang/allegro/pstchip.dat
   Finished reading F:/cundang/allegro/pstchip.dat (00:00:00.10)
Starting to read F:/cundang/allegro/pstxprt.dat
   Finished reading F:/cundang/allegro/pstxprt.dat (00:00:00.00)
Starting to read F:/cundang/allegro/pstxnet.dat
   Finished reading F:/cundang/allegro/pstxnet.dat (00:00:00.00)
------ Oversights/Warnings/Errors ------

#1   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'CAPPR150-400X500' for device 'CAP_CAPPR150-400X500_470UF' not found in PSMPATH or must be "dbdoctor"ed.
#2   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol '254-2P' for device 'B2S_2_254-2P_B2S' not found in PSMPATH or must be "dbdoctor"ed.
#3   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'RES650-320X170' for device 'R_RES650-320X170_10K' not found in PSMPATH or must be "dbdoctor"ed.
#4   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'DIP8' for device 'LM358_2_DIP8_LM358' not found in PSMPATH or must be "dbdoctor"ed.
    Alternatively, the JEDEC_TYPE is not defined for the device in the pstchip.dat.
#5   WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'DIP8' for device 'LM358_1_DIP8_LM358' not found in PSMPATH or must be "dbdoctor"ed.
    Alternatively, the JEDEC_TYPE is not defined for the device in the pstchip.dat.
------ Library Paths ------
MODULEPATH =  .
           C:/Cadence/SPB_16.3/share/local/pcb/modules
PSMPATH =  .
           symbols
           ..
           ../symbols
           C:/Cadence/SPB_16.3/share/local/pcb/symbols
           C:/Cadence/SPB_16.3/share/pcb/pcb_lib/symbols
           C:/Cadence/SPB_16.3/share/pcb/allegrolib/symbols
           D:\SPB_DATA\ALLEGRO LIB\
PADPATH =  .
           symbols
           ..
           ../symbols
           C:/Cadence/SPB_16.3/share/local/pcb/padstacks
           C:/Cadence/SPB_16.3/share/pcb/pcb_lib/symbols
           C:/Cadence/SPB_16.3/share/pcb/allegrolib/symbols
           D:\SPB_Data\allegro lib\

------ Summary Statistics ------

netrev run on Sep 26 22:31:00 2009
   DESIGN NAME : '123'
   PACKAGING ON Jan  3 2011 16:39:28
   COMPILE 'logic'
   CHECK_PIN_NAMES OFF
   CROSS_REFERENCE OFF
   FEEDBACK OFF
   INCREMENTAL OFF
   INTERFACE_TYPE PHYSICAL
   MAX_ERRORS 500
   MERGE_MINIMUM 5
   NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
   NET_NAME_LENGTH 24
   OVERSIGHTS ON
   REPLACE_CHECK OFF
   SINGLE_NODE_NETS ON
   SPLIT_MINIMUM 0
   SUPPRESS   20
   WARNINGS ON
No error detected
No oversight detected
  5 warnings detected
cpu time      0:01:00
elapsed time  0:00:00

库路径不对!找不到封装

可能是你的库没设置好。你看一下User Preferences Editor下的Design_paths是否有设库文件路经

已经设置了路径,   出现这样的问题不会是网表生成不对的问题吧?

我也碰到过两次这种问题,库路径都正确,后面好像是在数据库中删除,然后再重新增加一次又好了,没搞明白为什么?

沒有找到device文件!

我用db doctor 修复了遍文件  就好了  谁帮忙解释下

Cadence Allegro 培训套装,视频教学,直观易学

上一篇:从Protel99SE网表导入Allegro历程
下一篇:allegro 15.7中如何将两个没有网络的覆铜用过孔连接

PCB设计培训课程推荐详情>>

  网站地图