- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
导入网表时的错误!
录入:edatop.com 点击:
导入网表时出现:
#1 ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-200): Error with pin number 'M5' in device 'AML8726-M3_1121_IC-BGA405-065MM': 'Unable to find pin name in adfncpin.'.
#2 ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-165): Problems building functions in device 'AML8726-M3_1121_IC-BGA405-065MM': 'Unable to find pin name in adfncpin.'.
ERROR(SPMHNI-170): Device 'AML8726-M3_1121_IC-BGA405-065MM' has library errors. Unable to transfer to Allegro.
------ Summary Statistics ------
#3 Run stopped because errors were detected
netrev run on Oct 26 10:31:17 2012
DESIGN NAME : 'MBOX_8726M3_020912_V2'
PACKAGING ON Nov 17 2009 03:09:43
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
3 errors detected
No oversight detected
No warning detected
好像是pin name 的错误,但是原理图和封装都检查没问题 ,百度了的方法都解决不了!有人碰到过且解决了的啊!求解释!
#1 ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-200): Error with pin number 'M5' in device 'AML8726-M3_1121_IC-BGA405-065MM': 'Unable to find pin name in adfncpin.'.
#2 ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-165): Problems building functions in device 'AML8726-M3_1121_IC-BGA405-065MM': 'Unable to find pin name in adfncpin.'.
ERROR(SPMHNI-170): Device 'AML8726-M3_1121_IC-BGA405-065MM' has library errors. Unable to transfer to Allegro.
------ Summary Statistics ------
#3 Run stopped because errors were detected
netrev run on Oct 26 10:31:17 2012
DESIGN NAME : 'MBOX_8726M3_020912_V2'
PACKAGING ON Nov 17 2009 03:09:43
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
3 errors detected
No oversight detected
No warning detected
好像是pin name 的错误,但是原理图和封装都检查没问题 ,百度了的方法都解决不了!有人碰到过且解决了的啊!求解释!
pin name太长了,改短了就好了!不过很纳闷的是,有些pin name比M5的还长都没报错! 不知道怎么搞的!
你的PIN name中有这个字符.'. ?
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:allegro 模块设计复用问题