- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
导网表报警告,器件进不去!
录入:edatop.com 点击:
1 WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'BLOCK_3531T' for device 'D-SCON-45-2_10.0S_BLOCK_3531T_H' not found in PSMPATH or must be "dbdoctor"ed.
#2 WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'SON8-6_2-1_27' for device 'MPS1593_0_SON8-6_2-1_27_MPS1484' not found in PSMPATH or must be "dbdoctor"ed.
这上面的错误是不是说以上两个的器件的psm找不到?
WARNING(SPMHNI-194): Symbol 'BLOCK_3531T' for device 'D-SCON-45-2_10.0S_BLOCK_3531T_H' not found in PSMPATH or must be "dbdoctor"ed.
#2 WARNING(SPMHNI-192): Device/Symbol check warning detected.
WARNING(SPMHNI-194): Symbol 'SON8-6_2-1_27' for device 'MPS1593_0_SON8-6_2-1_27_MPS1484' not found in PSMPATH or must be "dbdoctor"ed.
这上面的错误是不是说以上两个的器件的psm找不到?
是的
谢谢已解决
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:15.5移动高速线时就卡死,必须重启。
下一篇:无法启动此程序,因为计算机中丢失cdsCommon.dll 请问这是什么问题啊?