- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
16.6到网表时报错问题
录入:edatop.com 点击:
到网表时报错如下,哪位大神帮忙看看什么问题?
#1 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_0R' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#2 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_330R' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#3 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_10MR' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#4 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'DB9_M_0965121770' for device 'DB9_M_09670095654_DB9_M_0965121' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#1 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_0R' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#2 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_330R' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#3 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'R0805' for device 'R_0_R0805_10MR' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
#4 WARNING(SPMHNI-192): Device/Symbol check warning detected. [help]
WARNING(SPMHNI-194): Symbol 'DB9_M_0965121770' for device 'DB9_M_09670095654_DB9_M_0965121' not found in PSMPATH or must be "dbdoctor"ed.
Database has a non-recoverable corruption. Contact Cadence customer support.
not found in psmpath....还是路径没设置好或者库里没这个零件 或者有这个零件没有psm....
咱还是多看看洋文提示,别害怕洋文,一见洋文看都不看就放弃了
多谢 kinglangji 的回复。
事实上,我逐一排查了路径问、psm文件及库这几个点,设置都没有问题。
后来,用其他人的16.6导入正常无误,判定是软件bug。
那就是去must be dbdoctor.....
其实重新create symbol也应该可以.
你要相信软件,如果他连这么简单的0805电阻导入网表都存在bug,那基本可以放弃他了
呵呵,言之有理呀。
Symbol 'R0805' for device 'R_0_R0805_0R' not found in PSMPATH,基本上看这个就够了
我怀疑系统设置问题。我的系统也遇到过这个问题。有些原理图中含有中文,结果在我的机器上不能产生网表,在别人的不同机器上却可以。
建议查查下面两中可能性:
1)你是否使用了中文或者非 ASCII字符串在原理图中。比如 90度 有人使用 90 加个小圆圈在右上角。这个小圆圈是非法字符。
2)你的系统是否是中文系统或者英文系统加上中文设置了。 多实验几种地区语言设置方法。
正解,灰常感谢!赞一个!
Cadence Allegro 培训套装,视频教学,直观易学
上一篇:about hotfix s37
下一篇:Allegro元器件库制作问题