- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
一个已经layout完成的板子,重新导入网表报错,求大侠指点。
录入:edatop.com 点击:
RIPUP_ETCH FALSE;
RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;
SCHEMATIC_DIRECTORY 'E:/work/PC5000214AV1.0/ELM/allegro';
BOARD_DIRECTORY '';
OLD_BOARD_NAME 'E:/work/PC5000214AV1.0/pcb/PC5000214AV1.0.brd';
NEW_BOARD_NAME 'E:/work/PC5000214AV1.0/pcb/PC5000214AV1.0.brd';
CmdLine: netrev -$ -i E:/work/PC5000214AV1.0/ELM/allegro -y 1 -z E:/work/PC5000214AV1.0/pcb/#Taaaaaa02404.tmp
------ Preparing to read pst files ------
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstchip.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstchip.dat (00:00:00.05)
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstxprt.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstxprt.dat (00:00:00.00)
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstxnet.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstxnet.dat (00:00:00.00)
------ Oversights/Warnings/Errors ------
------ Library Paths ------
MODULEPATH = .
d:/Cadence/SPB_16.3/share/local/pcb/modules
PSMPATH = E:\Library_spx\Symebols\
PADPATH = E:\Library_spx\PAD\
#1 Run stopped because errors were detected
netrev run on Oct 31 10:07:33 2014
DESIGN NAME : 'ELM0000203V1'
PACKAGING ON Nov 17 2009 03:09:43
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
1 errors detected
No oversight detected
No warning detected
RIPUP_SYMBOLS ALWAYS;
Missing symbol has error FALSE;
SCHEMATIC_DIRECTORY 'E:/work/PC5000214AV1.0/ELM/allegro';
BOARD_DIRECTORY '';
OLD_BOARD_NAME 'E:/work/PC5000214AV1.0/pcb/PC5000214AV1.0.brd';
NEW_BOARD_NAME 'E:/work/PC5000214AV1.0/pcb/PC5000214AV1.0.brd';
CmdLine: netrev -$ -i E:/work/PC5000214AV1.0/ELM/allegro -y 1 -z E:/work/PC5000214AV1.0/pcb/#Taaaaaa02404.tmp
------ Preparing to read pst files ------
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstchip.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstchip.dat (00:00:00.05)
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstxprt.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstxprt.dat (00:00:00.00)
Starting to read E:/work/PC5000214AV1.0/ELM/allegro/pstxnet.dat
Finished reading E:/work/PC5000214AV1.0/ELM/allegro/pstxnet.dat (00:00:00.00)
------ Oversights/Warnings/Errors ------
------ Library Paths ------
MODULEPATH = .
d:/Cadence/SPB_16.3/share/local/pcb/modules
PSMPATH = E:\Library_spx\Symebols\
PADPATH = E:\Library_spx\PAD\
#1 Run stopped because errors were detected
netrev run on Oct 31 10:07:33 2014
DESIGN NAME : 'ELM0000203V1'
PACKAGING ON Nov 17 2009 03:09:43
COMPILE 'logic'
CHECK_PIN_NAMES OFF
CROSS_REFERENCE OFF
FEEDBACK OFF
INCREMENTAL OFF
INTERFACE_TYPE PHYSICAL
MAX_ERRORS 500
MERGE_MINIMUM 5
NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|'
NET_NAME_LENGTH 24
OVERSIGHTS ON
REPLACE_CHECK OFF
SINGLE_NODE_NETS ON
SPLIT_MINIMUM 0
SUPPRESS 20
WARNINGS ON
1 errors detected
No oversight detected
No warning detected
没人遇到过这样的错误吗?
你是不是准备修改封装 。那就要把那个封装先删除掉,不然导不进去(这是画完的),可能原因就是这样我也遇到过。
不是修改封装,是原来板子上有几个器件是板子画好后手动放上去的,位号丝印是R*,我想重新导网表更新,总是导不进去。哪位高人有没有方法可以直接将R*修改为R23之类的