#1   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_10.5K/1%'. Package property error: 'VALUE'='10.5KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_10.5K/1%' has library errors. Unable to transfer to Allegro.
#2   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_215K/1%'. Package property error: 'VALUE'='215KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_215K/1%' has library errors. Unable to transfer to Allegro.
#3   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_17.4K/1%'. Package property error: 'VALUE'='17.4KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_17.4K/1%' has library errors. Unable to transfer to Allegro.
#4   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_90.9K/1%'. Package property error: 'VALUE'='90.9KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_90.9K/1%' has library errors. Unable to transfer to Allegro.
#5   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_147K/1%'. Package property error: 'VALUE'='147KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_147K/1%' has library errors. Unable to transfer to Allegro.
#6   ERROR(SPMHNI-176): Device library error detected.
ERROR(SPMHNI-190): Device problem 'RESISTOR_0402_142K/1%'. Package property error: 'VALUE'='142KΩ/1%'. Illegal character(s) present in the name or value..
ERROR(SPMHNI-170): Device 'RESISTOR_0402_142K/1%' has library errors. Unable to transfer to Allegro.

非法字符呀

Illegal character(s) present in the name or value..名字或者数值里面存在非法字符

我想第一个来说,没有想到楼上的说了。

;P

"Ω"是非法字符

我认为是“10.5KΩ/1%”中的“.”产生的问题,在capture软件中是不识别,空格  点 等一些字符的   小编可以试着改成:10k5/1%或者其他类似表示方式试试

把part 中属性里的device这一栏的删除掉.可以全部选择删除整栏

device这一栏在哪里啊?能否截图,谢谢

选中表格中这一行,全部删除.
实在不知道怎么上传图片啊,每次都是圈圈的状态

封装非法字符问题,说的不是很明确么,把“.”这类全改了如_就行

. Ω 都是非法字符

谢谢,是Ω是非法字符