• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > 电子设计 > PCB设计 > Allegro PCB技术问答 > 網絡表導入有錯誤,請幫忙看一下

網絡表導入有錯誤,請幫忙看一下

录入:edatop.com     点击:


#1   WARNING(304) Device/Symbol check warning detected.

Symbol 'T90-A90XFSMD' for device 'GAS_TUBE_90V_T90-A90XFSMD_T90-A' not found in PSMPATH or must be "dbdoctor"ed.

#2   WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-0402' for device 'CAP_0_CAP-0402_0.1UF' not found in PSMPATH or must be "dbdoctor"ed.

#3   WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-0402' for device 'CAP_0_CAP-0402_C' not found in PSMPATH or must be "dbdoctor"ed.

#4   WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-0402' for device 'CAP_1_CAP-0402_C' not found in PSMPATH or must be "dbdoctor"ed.

#5   WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-0402' for device 'CAP_0_CAP-0402_0.01UF' not found in PSMPATH or must be "dbdoctor"ed.

#6   WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-0603' for device 'CAP_0_CAP-0603_4.7UF' not found in PSMPATH or must be "dbdoctor"ed.

該怎麽修改阿?都不知道問題在哪

 SMPATH路径下面找不到文件

把封装画好放进库里
我的就是:

PSMPATH =  .
           symbols
           ..
           ../symbols
           C:/Cadence/SPB_15.5/share/local/pcb/symbols
           C:/Cadence/SPB_15.5/share/pcb/pcb_lib/symbols
           C:/Cadence/SPB_15.5/share/pcb/allegrolib/symbols

Cadence Allegro 培训套装,视频教学,直观易学

上一篇:关于flash
下一篇:如何修改精度啊?

PCB设计培训课程推荐详情>>

  网站地图