• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > 电子设计 > PCB设计 > Allegro PCB技术问答 > 第一次用ORCAD发送网表到Allegro遇见的问题(求大虾指点)

第一次用ORCAD发送网表到Allegro遇见的问题(求大虾指点)

录入:edatop.com     点击:
用ORCAD生成网表,发送到Allegro.报错误。因为我第一次用,所以PCB方面应该没有库。我想问下是不是因为没有找到PCB库,才报的错误还是因为破解不完整的问题?
#492 Error   [ALG0031] Pin number missing from Pin "1" of Package CAP , C110: EU07GBN-250-02033-011, 07_POWER & LED Display (3.05, 1.25). All pins should be numbered.
#493 Error   [ALG0031] Pin number missing from Pin "2" of Package CAP , C110: EU07GBN-250-02033-011, 07_POWER & LED Display (3.05, 1.25). All pins should be numbered.
#494 Error   [ALG0031] Pin number missing from Pin "1" of Package CAP , C100: EU07GBN-250-02033-011, 03_GIGA Switch AR8328N (9.30, 11.75). All pins should be numbered.
#495 Error   [ALG0031] Pin number missing from Pin "2" of Package CAP , C100: EU07GBN-250-02033-011, 03_GIGA Switch AR8328N (9.30, 11.75). All pins should be numbered.


想知道是否因为没有封装的缘故很简单,在allegro库里增加一个你原理图中指定的封装名称(至少管脚数量要求一致),然后再导入网表,看看错误中关于你修改的这个元件的错误还在不在。找到问题所在就可以对症下药了。

原理图中CAP的封装没有1、2脚,选中CAP封装,右键Edit Part,点击pin,在pin number中添加就可以了

封装没有管脚1、2要不改原理图库的管脚名字,或者改封装的管脚名字,把原理图的管脚名字和封装管脚名字一致就行了

楼上正解,顶!

学习中。

学习中。

Cadence Allegro 培训套装,视频教学,直观易学

上一篇:为什么我的PgUp,PgDn,Home和End,Tab键设置快捷键没用?
下一篇:Skill:将Board file从16.x降到15.7 (转)

PCB设计培训课程推荐详情>>

  网站地图