我从ORCAD转出ALLEGRO网表,从POWERPCB导出元件库,现在从Allegro PCB导入网表,出现一堆问题:

Cadence Design Systems, Inc. netrev 15.2 Mon May 09 08:45:57 2005(C) Copyright 2002 Cadence Design Systems, Inc.

------ Directives ------

RIPUP_ETCH FALSE;RIPUP_SYMBOLS ALWAYS;MISSING SYMBOL AS ERROR FALSE;SCHEMATIC_DIRECTORY 'F:\SFP\NEW\002';BOARD_DIRECTORY '';OLD_BOARD_NAME '01.brd';NEW_BOARD_NAME '01.brd';

CmdLine: netrev -$ -5 -i F:\SFP\NEW\002 -y 1 F:\SFP\NEW\002\#Taaaaaa01376.tmp

------ Preparing to read pst files ------

Starting to read F:/SFP/NEW/002/pstchip.dat Finished reading F:/SFP/NEW/002/pstchip.dat (00:00:00.24)Starting to read F:/SFP/NEW/002/pstxprt.dat Finished reading F:/SFP/NEW/002/pstxprt.dat (00:00:00.00)Starting to read F:/SFP/NEW/002/pstxnet.dat Finished reading F:/SFP/NEW/002/pstxnet.dat (00:00:00.04)

------ Oversights/Warnings/Errors ------

#1 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-CAP' for device 'CAP NP_0_0603-CAP_0.1UF' not found in PSMPATH or must be "dbdoctor"ed.

#2 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-CAP' for device 'CAP NP_0_0603-CAP_20PF' not found in PSMPATH or must be "dbdoctor"ed.

#3 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-CAP' for device 'CAP NP_0_0603-CAP_1UF (NC)' not found in PSMPATH or must be "dbdoctor"ed.

#4 WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-C' for device 'CAP-C_CAP-C_47UF' not found in PSMPATH or must be "dbdoctor"ed.

#5 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-CAP' for device 'CAP NP_0_0603-CAP_0.1UF_1' not found in PSMPATH or must be "dbdoctor"ed.

#6 WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-C' for device 'CAP-C_CAP-C_10UF' not found in PSMPATH or must be "dbdoctor"ed.

#7 WARNING(304) Device/Symbol check warning detected.

Symbol 'CAP-B' for device 'CAP-C_CAP-B_10UF' not found in PSMPATH or must be "dbdoctor"ed.

#1 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'LED' for device 'LED_LED_LED': Couldn't find padstack: PAD3 due to Unable to load Flash symbol PAD3.

#2 ERROR(305) Device/Symbol check error detected.

Unable to load symbol '1N5819' for device 'DIODE ZENER_1N5819_1N5819': Couldn't find padstack: PAD4 due to Unable to load Flash symbol PAD4.

#3 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'LL34' for device 'DIODE ZENER_LL34_1N4148': Couldn't find padstack: PAD5 due to Unable to load Flash symbol PAD5.

#4 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'IDC30' for device 'IDC30_IDC30_IDC30': Couldn't find padstack: PAD6 due to Unable to load Flash symbol PAD6.

#5 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'PLG3' for device 'PLG3_0_PLG3_PLG3 (NC)': Couldn't find padstack: PAD8 due to Unable to load Flash symbol PAD8.

#6 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'CON5' for device 'CON5_0_CON5_CON5': Couldn't find padstack: PAD3 due to Unable to load Flash symbol PAD3.

#7 ERROR(305) Device/Symbol check error detected.

Unable to load symbol '32PIN' for device 'GF_0_32PIN_GF': Couldn't find padstack: PAD11 due to Unable to load Flash symbol PAD11.

#8 WARNING(304) Device/Symbol check warning detected.

Symbol 'IDC10' for device 'IDC10_0_IDC10_IDC10' not found in PSMPATH or must be "dbdoctor"ed.

#8 ERROR(305) Device/Symbol check error detected.

Unable to load symbol '1206N' for device 'BEAD_1206N_BEAD': Couldn't find padstack: PAD14 due to Unable to load Flash symbol PAD14.

#9 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_4.7K' not found in PSMPATH or must be "dbdoctor"ed.

#10 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_3K' not found in PSMPATH or must be "dbdoctor"ed.

#11 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_2K' not found in PSMPATH or must be "dbdoctor"ed.

#12 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_22' not found in PSMPATH or must be "dbdoctor"ed.

#13 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_510' not found in PSMPATH or must be "dbdoctor"ed.

#14 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_3K (NC)' not found in PSMPATH or must be "dbdoctor"ed.

#15 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_22(NC)' not found in PSMPATH or must be "dbdoctor"ed.

#16 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_1K (NC)' not found in PSMPATH or must be "dbdoctor"ed.

#17 WARNING(304) Device/Symbol check warning detected.

Symbol '0603-RES' for device 'R_0603-RES_1K' not found in PSMPATH or must be "dbdoctor"ed.

#9 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'RA8A' for device 'RN_RA8A_22': Couldn't find padstack: PAD15 due to Unable to load Flash symbol PAD15.

#10 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'RA8A' for device 'RN_RA8A_220': Couldn't find padstack: PAD15 due to Unable to load Flash symbol PAD15.

#11 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'SOIC14' for device 'MAX1482_0_SOIC14_MAX1482': Couldn't find padstack: PAD17 due to Unable to load Flash symbol PAD17.

#12 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'SOIC16' for device 'MAX232A_SOIC16_MAX232 (NC)': Couldn't find padstack: PAD18 due to Unable to load Flash symbol PAD18.

#13 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'SOIC14' for device 'DM7404_SOIC14_74HC04': Couldn't find padstack: PAD17 due to Unable to load Flash symbol PAD17.

#14 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'TO263' for device 'LM1084-33_TO263_LM1084-3.3': Couldn't find padstack: PAD19 due to Unable to load Flash symbol PAD19.

#15 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'SOIC8' for device 'AT24C04_SOIC8_AT24C02': Couldn't find padstack: PAD17 due to Unable to load Flash symbol PAD17.

#16 ERROR(305) Device/Symbol check error detected.

Unable to load symbol 'DIP40' for device 'W78E58B_0_DIP40_W77E58': Couldn't find padstack: PAD21 due to Unable to load Flash symbol PAD21.

#18 WARNING(304) Device/Symbol check warning detected.

Symbol 'CRYSTAL-SMD' for device 'CRYSTAL_CRYSTAL-SMD_11.0592MHZ' not found in PSMPATH or must be "dbdoctor"ed.

------ Library Paths ------MODULEPATH = . C:\Cadence\SPB_15.2\share\local\pcb/modules

PSMPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/symbols C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

PADPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/padstacks C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

------ Summary Statistics ------

#17 ERROR(102) Run stopped because errors were detected

netrev run on May 9 8:45:56 2005 DESIGN NAME : 'EDFA' PACKAGING ON Apr 6 2004 19:58:38

COMPILE 'logic' CHECK_PIN_NAMES OFF CROSS_REFERENCE OFF FEEDBACK OFF INCREMENTAL OFF INTERFACE_TYPE PHYSICAL MAX_ERRORS 500 MERGE_MINIMUM 5 NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|' NET_NAME_LENGTH 24 OVERSIGHTS ON REPLACE_CHECK OFF SINGLE_NODE_NETS ON SPLIT_MINIMUM 0 SUPPRESS 20 WARNINGS ON

17 errors detectedNo oversight detected18 warnings detected

cpu time 0:03:44elapsed time 0:00:02

我看元件库路径是正确的... ...

那时因为你有的零件封装和你的原理图不否

没有封装不一致的情况,因为我可以导到POWER PCB,从POWER PCB 导到 Allegro PCB,再从Allegro PCB导出元件库。

我不明白“must be "dbdoctor"ed”是什么意思?

PAD1-PAD21要我自己做吗?

你的这些warnings/errors是在Allegro中import logic 的时候出现吗?

我import logic 倒是没有错误,但在Place -Manually某个器件的时候,提示器件不存在

我检查了封装库的路径,是正确的,而且该器件的封装也在

原理图中填写的FOOTPRINT也是正确的

莫名其妙的,不晓得是什么原因

Cadence Design Systems, Inc. netrev 15.2 Tue May 10 16:41:05 2005(C) Copyright 2002 Cadence Design Systems, Inc.

------ Directives ------

RIPUP_ETCH FALSE;RIPUP_SYMBOLS ALWAYS;MISSING SYMBOL AS ERROR FALSE;SCHEMATIC_DIRECTORY 'F:\SFP\NEW';BOARD_DIRECTORY '';OLD_BOARD_NAME '1.brd';NEW_BOARD_NAME '1.brd';

CmdLine: netrev -$ -5 -i F:\SFP\NEW -y 1 F:\SFP\NEW\#Taaaaaa00712.tmp

------ Preparing to read pst files ------

Starting to read F:/SFP/NEW/pstchip.dat Finished reading F:/SFP/NEW/pstchip.dat (00:00:00.00)Starting to read F:/SFP/NEW/pstxprt.dat Finished reading F:/SFP/NEW/pstxprt.dat (00:00:00.01)Starting to read F:/SFP/NEW/pstxnet.dat Finished reading F:/SFP/NEW/pstxnet.dat (00:00:00.01)

------ Oversights/Warnings/Errors ------

#1 ERROR(305) Device/Symbol check error detected.

Error finding symbol 'IDC30' for device 'IDC30_IDC30_IDC30': 'Symbol extents are greater than drawing extents'.

#2 ERROR(305) Device/Symbol check error detected.

Error finding symbol '32PIN' for device 'GF_0_32PIN_GF': 'Symbol extents are greater than drawing extents'.

#3 ERROR(305) Device/Symbol check error detected.

Error finding symbol 'IDC10' for device 'IDC10_0_IDC10_IDC10': 'Symbol extents are greater than drawing extents'.

#4 ERROR(305) Device/Symbol check error detected.

Error finding symbol 'DIP40' for device 'W78E58B_0_DIP40_W77E58': 'Symbol extents are greater than drawing extents'.

------ Library Paths ------MODULEPATH = . C:\Cadence\SPB_15.2\share\local\pcb/modules

PSMPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/symbols C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

PADPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/padstacks C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

------ Summary Statistics ------

#5 ERROR(102) Run stopped because errors were detected

netrev run on May 10 16:41:05 2005 DESIGN NAME : 'EDFA' PACKAGING ON Apr 6 2004 19:58:38

COMPILE 'logic' CHECK_PIN_NAMES OFF CROSS_REFERENCE OFF FEEDBACK OFF INCREMENTAL OFF INTERFACE_TYPE PHYSICAL MAX_ERRORS 500 MERGE_MINIMUM 5 NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|' NET_NAME_LENGTH 24 OVERSIGHTS ON REPLACE_CHECK OFF SINGLE_NODE_NETS ON SPLIT_MINIMUM 0 SUPPRESS 20 WARNINGS ON

5 errors detected No oversight detected No warning detected

cpu time 0:00:30elapsed time 0:00:00

一路下去,还剩4个,真不知什么原因。

功夫不负有心人。全部PASS

Cadence Design Systems, Inc. netrev 15.2 Wed May 11 08:27:07 2005(C) Copyright 2002 Cadence Design Systems, Inc.

------ Directives ------

RIPUP_ETCH FALSE;RIPUP_SYMBOLS ALWAYS;MISSING SYMBOL AS ERROR FALSE;SCHEMATIC_DIRECTORY 'F:\SFP\NEW';BOARD_DIRECTORY '';OLD_BOARD_NAME '1.brd';NEW_BOARD_NAME '1.brd';

CmdLine: netrev -$ -5 -i F:\SFP\NEW -y 1 F:\SFP\NEW\#Taaaaaa00712.tmp

------ Preparing to read pst files ------

Starting to read F:/SFP/NEW/pstchip.dat Finished reading F:/SFP/NEW/pstchip.dat (00:00:00.00)Starting to read F:/SFP/NEW/pstxprt.dat Finished reading F:/SFP/NEW/pstxprt.dat (00:00:00.01)Starting to read F:/SFP/NEW/pstxnet.dat Finished reading F:/SFP/NEW/pstxnet.dat (00:00:00.01)

------ Oversights/Warnings/Errors ------

------ Library Paths ------MODULEPATH = . C:\Cadence\SPB_15.2\share\local\pcb/modules

PSMPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/symbols C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

PADPATH = . symbols .. ../symbols C:\Cadence\SPB_15.2\share\local\pcb/padstacks C:\Cadence\SPB_15.2\share\pcb/pcb_lib/symbols C:\Cadence\SPB_15.2\share\pcb/allegrolib/symbols

------ Summary Statistics ------

netrev run on May 11 8:27:07 2005 DESIGN NAME : 'EDFA' PACKAGING ON Apr 6 2004 19:58:38

COMPILE 'logic' CHECK_PIN_NAMES OFF CROSS_REFERENCE OFF FEEDBACK OFF INCREMENTAL OFF INTERFACE_TYPE PHYSICAL MAX_ERRORS 500 MERGE_MINIMUM 5 NET_NAME_CHARS '#%&()*+-./:=>?@[]^_`|' NET_NAME_LENGTH 24 OVERSIGHTS ON REPLACE_CHECK OFF SINGLE_NODE_NETS ON SPLIT_MINIMUM 0 SUPPRESS 20 WARNINGS ON

No error detected No oversight detected No warning detected

cpu time 0:00:36elapsed time 0:00:00

ice4521,我遇到和你同样的问题,能详细介绍一下你是怎么搞定的吗?谢谢!

1.not found in PSMPATH or must be "dbdoctor"ed.
没有找到文件路径或未检查的元件(不符合Symbol 要求)
2.Couldn't find padstack
元件Symbol里找不到padstack(库里没有这个padstack,要重新建立)
3.Symbol extents are greater than drawing extents
元件尺寸已经大于导入窗口尺寸(加大导入窗口尺寸)

all right, thanks very much, I'm keeping on trying it

Symbol extents are greater than drawing extents