CST2013: Q-Factor Special Settings
Post Processing: 2D/3D Field Post Processing Loss and Q Specials...
This dialog offers the possibility to define some special settings concerning the loss and Q-factor calculation.
Boundaries for integration frame
Xmin, Xmax, Ymin, Ymax, Zmin, Zmax: In the main Q-Factor Calculation dialog, the background material (if PEC) and the boundaries (if PEC) are included in the loss calculation under ”**Cond. Enclosure**” by defining a finite conductivity value for the perturbation method. In any event, if some boundaries should not be considered for the loss calculation, you can uncheck the corresponding boxes here.
Save 3D dielectric loss data for plot
Check this box if you want to plot the losses in lossy dielectric material. Generated data will be put into the Navigation Tree under 2D/3D ResultsPower Loss Dens. This feature cannot be used to generate plots of the surface losses.
OK
Takes the current settings and closes the dialog box.
Cancel
Closes this dialog box without performing any further action.
Help
Shows this help text.