- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
CST2013: Import Problem Handling
This page contains a list of the most important warning and information messages together with a detailed explanation of the meaning and proposal for handling and resolution.
Model size is smaller than a valid box.
The geometrical data could not be correctly imported because the units are not correctly set.
Modeling and meshing operations may fail!
Solutions:
Change unit dimensions, and check "Scale to current unit" in the import options.
If the "Import file units" have to be specified then set them to a smaller dimension than the project units.
For OBJ imports you may change the "Scale factor" instead of setting the "Import file units".
Model size exceeds valid box.
The geometrical data could not be correctly imported because the units are not correctly set.
Modeling and meshing operations may fail!
Solutions:
Change unit dimensions, and check "Scale to current unit" in the import options.
If the "Import file units" have to be specified then set them to a larger dimension than the project units.
For OBJ imports you may change the "Scale factor" instead of setting the "Import file units".
Coordinates are outside the dynamic range [-1e4, 1e4] of the 3D Modeler.
Modeling and meshing operations may fail!
Solutions:
Scale and translate the objects as appropriate into the dynamic range of the 3D Modeler.
The quality of the imported model can be improved by setting the project unit to "xxx", and importing the model again with the option "Scale to current unit".
The geometrical data of the CATIA5, STEP, PROE or Inventor file were not modelled with the same accuracy as that of the 3D Modeler. Therefore, the quality of the import is not as good as it is needed for further operations on the imported shapes. In order to improve the quality of the imported model use the following steps.
Solution:
Set the project unit before the import to "xxx".
Activate the import option "Scale to current unit" and perform the import.
After the import, set the project unit to the one you desire.
Now scale the model with an appropriate scale factor using the transform dialog. (i.e. if the project unit before the import was "m", and the project unit after the import is set to "mm" as suggested in step 3, then you need to use a scale factor of 1000)
See also
Object Creation and Operations Problem Handling
CST微波工作室培训课程套装,专家讲解,视频教学,帮助您快速学习掌握CST设计应用
上一篇:CST2013: How to Setup a Coupled HF - Thermal Simulation
下一篇:CST2013: Low Frequency Solvers Problem Handling
最全面、最专业的CST微波工作室视频培训课程,可以帮助您从零开始,全面系统学习CST的设计应用【More..】
频道总排行
- CST2013: Mesh Problem Handling
- CST2013: Field Source Overview
- CST2013: Discrete Port Overview
- CST2013: Sources and Boundary C
- CST2013: Multipin Port Overview
- CST2013: Farfield Overview
- CST2013: Waveguide Port
- CST2013: Frequency Domain Solver
- CST2013: Import ODB++ Files
- CST2013: Settings for Floquet B