- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
CST中6个error的解决方案
1. The port mode Eigensolver(本征求解器) failed because the maximum number of iterations has been reached.
2. Single-ended definition requires a separate mode set for each pin .Please check waveguide Port Number.
3. The propagation constant of mode1 is zero ,cannot continue.
4. Waveguide for port nuber 1 is too short. The waveguide must be homogeneous for at least three mesh planes along propagation direction.
5. Too few conductors detected .Conductors might be short-circuited in port plane.
6. On port 2 multiple potential definitions of the same set are located on one conductor ,or a symmetry condition is incompatible with the potential definitions.
微波仿真论坛上看到的,除了第4个问题是因为端口处没有加密到3个网格以外,其余的都还不知道怎么解决,拿来和大家一起探讨下。
我用CST有些时间了,您遇到的问题主要都是波导端口的定义和端口处网格的定义上,答案如下。希望帮得上你。
1、这个提示并不是真正的本征模求解器的问题。CST的2008版以后的版本中对波导端口的求解精度进行了提高,每次进行仿真的时候,会自动对波导端口进行自适应网格收敛性分析,并得到精确的结果。这里出现这样的错误提示:主要是波导端口处的起始网格设置太粗,经过了4次(缺省值)网格迭代后仍不能达到指定的1%(缺省值)的精度要求,所以计算停止了。解决方法:提高端口处的起始网格或者取消自适应分析,更建议用前者。
2、要进行单端S参量计算,是要定义多芯端口的。CST丛书3中有多芯端口定义的详细介绍,老兄可以买来看看。也不贵!
3、真不知道您是怎样定义的波导端口,波导端口的传播常数为0啊,这当然不能继续进行下去了。
4、还是波导端口的问题,波导端口的定义要求端口面处,传播方向上至少要有3个网格才行的。
5、同样,断口处的网格太少,端口面上都短路了。
6、多芯端口定义的不对,这个错误说明您把多个电势定义到同一根内导体上了。这怎么行!建议你看看丛书3或者他们有本丛书9里面有个多层差分线的例子介绍的也挺好。
其实楼上下次遇到问题时,还可以把模型一并上传。这样帮你解答起来更有针对性地。:19bb
回答的很好啊,不错,支持一下
:27bb
:27bb :27bb
CST的丛书3中有波导端口和多芯端口定义的详细介绍。微波技术网上也有对多芯端口的简单介绍啊。如附件就是从这里下载的。
http://imw.mwhrf.com/thread-7956-1-2.html
呵呵……
2楼好强大,推荐做CST版面小编,自愧不如,同时一并感谢
微网的热心人就是多阿,二楼讲解的很清楚哈:27bb
我翻译的,呵呵~
:27bb :27bb :27bb :27bb
真的很不错呀 希望继续加油 继续交流
申明:网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程。
上一篇:请教CST2008建模时出错?
下一篇:CST新闻-最新技术成果