• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > CST > CST使用问答 > CST STUDIO SUITE 2011 Service Pack 1 2011年3月2日已发布

CST STUDIO SUITE 2011 Service Pack 1 2011年3月2日已发布

录入:edatop.com     点击:
Changes in the Service Packs

General / Environment
􀁺 Added filtering option to the result curve selection dialog box. New Feature!
􀁺 Changing the description of a parameter will no longer display an update message.
􀁺 Avoided wrong error message under Linux in case a non-unique index is created in the result database.
􀁺 Removed obsolete backup folders on start of a new optimization.
􀁺 Reduced the amount of required memory during an optimization with many parameters.
􀁺 Tables with only one curve do not show a curve label any longer.
CST License Manager
􀁺 Number of active licenses displayed on the front page.
􀁺 Connect to Remote/Local server buttons displayed on the front page.
􀁺 Show Log and Save Status moved to the front page.
􀁺 Added new Reload button for Log File viewer and automatic scroll to the end of the file.
Modeler / Structure Visualization
􀁺 Repaired "Shift+Z" shortcut to activate the cutting plane.
􀁺 Fixed special bending issue on doubly-curved face where thickening of sheet did not work afterwards.
􀁺 Improved sensitivity analysis dialog box in order to inform the user about parameters which are not supported by the sensitivity analysis.
􀁺 Fixed incorrect invalidation of solver type when only tables are deleted in modeler.
EDA Import
􀁺 PADS Import: Added slotted drill holes and cutouts within board outline.
􀁺 Zuken CR5000 Import: Consider flipped attribute for vias.
􀁺 Cadence APD/SiP Import: Allow case of BGA with no pins.
􀁺 Fixed loading of CST *.dat files in PCB import dialog.
􀁺 Correctly consider net selection when creating 3D model of PCB.
􀁺 PCB import dialog: Added automatic switching to etch geometries after pressing preview. New Feature!
􀁺 Synchronized interpretation of the PCB layer stack-up between MWS and PCBS.
􀁺 Fixed problem of loosing layer selection.
􀁺 Cadence-CST Simulation Plugin: Fixed problems with path names containing spaces or a reference to a network-drive.
􀁺 Cadence-CST Simulation Plugin: Enabled functionality for Cadence APD layouts.
􀁺 Avoided double history update after editing PCB-import settings.
􀁺 ODB++ Import: Correctly consider cutouts in pad figures.
Distributed Computing (DC)
􀁺 Fixed race condition when submitting jobs while project is saving.
􀁺 Parameter sweep log file will not be deleted any longer at the end of a distributed parameter sweep.
􀁺 Improved MainController to Frontend transfer speed.
􀁺 Fixed problems when connection to MainController timed out.
Hexhedral (Hex) Mesh
􀁺 Improved startup procedure of matrix calculator for machines with a high number of cores.
􀁺 Enhanced warning mechanism if two bodies overlap each other during simulation setup.
CST MICROWAVE STUDIO - General
􀁺 Fixed Smith-Chart for S-parameters from simultaneous excitations.
􀁺 Farfield source files include position and rotation of the source. New Feature!
􀁺 Farfield sources with multipoles and distributed frequency samples (DC) repaired.
􀁺 Linux/Windows differences for farfield sources with multipoles fixed.
􀁺 Farfield sources support relative paths. New Feature!
􀁺 Automatic calculation of broadband farfield quantities. New Feature!
􀁺 SAR calculation sums up tissue volume and mass only in cells which have losses.
􀁺 Scaling of farfields with array feature corrected.
􀁺 Plotting of monostatic scattering results at theta=0/180 deg. improved.
􀁺 Automatic determination of farfield source size improved.
CST MICROWAVE STUDIO - Transient Solver
􀁺 Fixed phase computation for voltage and current monitors.
􀁺 Removed obsolete navigation tree entries for post processing of complex AR-filtered S-parameters.
􀁺 Fixed phase de-embedding for AR-filtered S-parameters.
CST MICROWAVE STUDIO - Frequency Domain (FD) Solvers
􀁺 Curved elements are now available for the frequency domain solver with tetrahedral mesh. New Feature!
􀁺 The visible frequency range of S-parameter results was sometimes reduced after continuing the solver run with modified sampling list.
􀁺 Combine results of multiple tetrahedral FD solver farfields repaired.
􀁺 Unit cell farfield contributions from Zmin and Zmax are now added if no de-coupling planes are present.
􀁺 The tetrahedral FD solver terminated abnormally for gyromagnetic materials with zero biasing field.
􀁺 Improved the FD solver's handling of frequency sampling intervals with a limited number of samples in case of frequency distributed computing.
􀁺 With frequency distributed computing, the S-parameter error progression is now displayed versus the true number of calculated samples.
􀁺 The FD solver calculated one frequency sample too few for some automatic sampling intervals with a limited number of samples.
􀁺 The minimum number of samples for frequency sample distributed computing now includes the number of subsequent S-parameter checks.
􀁺 With frequency sample distributed computing, the solver run was sometimes started locally after continuing the run with new monitors or samples.
􀁺 The majority of possible errors and warnings is now displayed before the tetrahedral mesh generation.
􀁺 Farfield contribution from Floquet modes of the lower hemisphere is now considered correctly.
􀁺 The tetrahedral FD solver terminated abnormally when using the ASCII signal storage mode.
􀁺 Made the detection of rectangular discrete face ports more tolerant.
􀁺 Resolved problems with reading the tetrahedral mesh after the processing of lossy metal sheets.
CST MICROWAVE STUDIO - Asymptotic Solver
􀁺 Fixed problem when setting consider for simulation flag after saving A solver project under a new name.
􀁺 Improved automatic combination of farfield sources.
􀁺 Added support for multipole farfield sources for asymptotic solver. New Feature!
􀁺 Fixed inconsistency in output of number of surfaces / triangles in status bar and solver log file.
􀁺 The asymptotic solver now stores intermediate result data upon abort. New Feature!
􀁺 Fixed a problem in detecting closed boundary condition.
􀁺 Changed default for theta cuts in angular sweeps to theta = 90.
CST EM STUDIO Solvers
􀁺 Repaired issue with source names ending with the character '.
CST PARTICLE STUDIO Solvers
􀁺 Improved emission of particle point sources close to PEC material in the tracking solver.
CST CABLE STUDIO
􀁺 Corrected cross section view for coupled segments.
CST PCB STUDIO
􀁺 2D (TL): Generate a non-lossy model in case of corresponding GUI setting for Ohmic losses.
􀁺 2D (TL): Allow thin solder mask layers; effective simulation of thin solder mask layers. New Feature!
􀁺 The correct pins are removed in the SI-TD dialog, if pins are sorted by nets.
􀁺 On editing the cell of the Stackup Manager table the input is automatically highlighted.
􀁺 Load Part Library feature added. New Feature!
􀁺 Allow running the PI solver on projects located on a network share.
CST MICROSTRIPES
􀁺 Added field plot visualization accelerators + / - to go to next / previous time step. New Feature!
􀁺 File import of CST MWS model into CST MS: Repaired issue of circuits with zero components.
􀁺 Forward animation now shows the next time step.
CST DESIGN STUDIO
􀁺 Added support for field sources in simulation project creation. New Feature!
􀁺 Improved parameter evaluations, especially for nested expressions.
􀁺 Fixed issues concerning parameter/model synchronization between CST DS and CST MWS.
􀁺 CST DS table plots remember which parameter was varied.
􀁺 Repaired problem with CST EMS source names ending with the character '.
􀁺 Repaired de-embedding of ideal transmission line blocks with losses.
􀁺 Fixed small randomness in link routes.
􀁺 Repaired problem with const. term for linear, controlled sources.
􀁺 Ensured that CalculateModesOnly flag is always consistent for MWS transient co-simulation.
􀁺 Fixed handling of port impedance interpolation in MWS co-simulation with discrete and waveguide ports.
􀁺 Resolved problem in port mode impedance calculation when running a MWS transient co-simulation.
􀁺 Fixed issue of doubly visible tree entries in a CST CS project.
􀁺 Removed tree visibility issue: In special situations the CST DS tree was hidden.
􀁺 Repaired problem when creating DS-Blocks via VBA.
􀁺 Incorrect recognition of CST MWS Exclude Port-Modes feature in CST DS resolved.
􀁺 Default time units for new CST DS projects changed to ns.
Result Templates / VBA / Macros / External Data Access
􀁺 New Wizard to import ASCII multi column data (Macros/Wizard/Data Import Wizard) New Feature!
􀁺 Farfield Result template now supports multiplexing efficiency option and broadband capability for div. gain/corr. coeff New Feature!
􀁺 Fixed selection of parameter via the VBA interface of the yield analysis .
􀁺 Added new VBA command Bending.ParamSweepAndOptimizerChecksResult to activate an internal check during parameter sweep and optimizer which verifies whether the sheets are entirely bent on the solid. New Feature!
􀁺 Result1DComplex object has a new function ZthPower to calculate complex powers. New Feature!

申明网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程

上一篇:请教CST MWS 中mesh density control
下一篇:CST MWS仿真喇叭天线

CST培训课程推荐详情>>

  网站地图