好吧,还没装上CST 2016的,你们被甩两条街了……,因为2016的SP1已经发布了。

Service Pack 2016.01General / Environment• Removed unnecessary wait cursors when a parameter sweep is started.• Parameter sweep dialog box is correctly shown when the sheets are toggled.• Fixed format error in ADS component export (ADS version 2015).• Pressing F7 after modifying a mesh independent parameter will no longer delete the mesh.• Fixed unnecessary result deletions when changing construction faces.• Improved performance of the DXF import while updating the history list. EDA Import / EDA Tools• Fixed that the etch factor type of conductor layers is not set correctly.• Corrected feature Consider component for PI Analysis. Distributed Computing (DC)• Fixed Folder does not exist error which might occur with distributed parameter sweep and distributed discretizer.• Fixed issue with too many open file handles for distributed parameter sweep. Hexahedral (Hex) Mesh• Improved performance for projects with a large number of solids. CST MICROWAVE STUDIO - Frequency Domain Solver (Tetrahedral Mesh)• Parametric changes are now considered also for the magnetostatic simulation in the biased ferrite workflow. CST MICROWAVE STUDIO - Integral Equation Solver• More robust S-parameter sweep for real ground materials with a high conductivity.• Improved automatic handling of real ground model type and added related option in the dialog box Special Integral Equation Solver Parameters.• Mesh is updated when real ground material is changed.• Fixed issue with possibly incorrect port modes for quad mesh. CST MICROWAVE STUDIO - Multilayer Solver• Fixed possible issue with unphysical modes when using Characteristic Mode Analysis (CMA). CST EM STUDIO• Improved convergence for accelerated preconditioner in the frequency domain solver.
• Added support for coil groups in the frequency domain solver.
• Fixed display of results unit for the impedance matrix in the frequency domain solver.• Improved convergence for non-linear problems if voltage driven coils are used in the time domain magnetoquasistatic solver.• Fixed an issue occurring when renaming coils and coil groups.• Fixed frequency value in the solver notes of the force calculation in the frequency domain solver.• Fixed the definition of components in motion of equation for translational problems. CST PARTICLE STUDIO Solvers• Fixed SEY data import so that new SEY data can be imported for a given material.• Repaired calculation of gamma when evaluating particle monitors in the tracking solver.• Fixed handling of particle sheets in tetrahedral tracking solver.• Improved collision detection in tetrahedral tracking solver in case of PEC background material.• Fixed handling of floating potentials in tetrahedral tracking solver.• Fixed visualization of PIC2DMonitor results in case of more than one particle source. CST PCB STUDIO• Fixed issue that the SI TD solver aborts with Unable to restore selection. CST BOARDCHECK• Fixed units for Pin position and Pin distance to via.• Rule Critical Net Isolation: Fixed that output value in table for Distance was not treated as a length but just as a float. CST DESIGN STUDIO• Avoid non-calculation of user probe results when calculation of automatic probe results fails.• Fixed failure to calculate frequency domain voltages and currents in transient co-simulation when time gating is enabled. Result Templates / VBA / Macros / External Data Access• Corrected the return value of the LumpedElement.GetProperties VBA command for the type argument.• New Result Template 2D 3D Results > Export 3D Field Result replaces former macro Export Field Data at UDF positions.

不止两条了...
好几十条街了都...

等多发几个SP先,免得有bug,哈哈

被甩好多了。今年发布的好早

感觉要到sp3sp4后才bug减少啊

申明网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程

上一篇:CST中后处理傅里叶变换请教
下一篇:electric monopole excitation的相关问题

CST培训课程推荐详情>>

  网站地图