• 易迪拓培训,专注于微波、射频、天线设计工程师的培养
首页 > CST > CST使用问答 > CST STUDIO SUITE 2015 Service Pack 4已发布

CST STUDIO SUITE 2015 Service Pack 4已发布

录入:edatop.com     点击:
CST官网今天发布CST STUDIO SUITE 2015 SP4,编译于8月7日。

General / Environment
􀁺 Corrected naming during fast model update for transformations with a new target component.
􀁺 Improved performance of the object properties dialog box for large models.
􀁺 Improved port deembedding orientation for certain cases.
􀁺 ADS import now reads the boundary conditions and the bounding box add space value correctly and creates discrete ports if possible.
􀁺 Fixed rare issues with corrupted CST files when stored on a shared drive in the network.
􀁺 Improved robustness of the writing of the data directory
􀁺 Improved mechanism for aborting a parameter sweep or an optimizer run.
􀁺 Support for using parameters from parts of Solidworks assemblies in the '3D CAD Parametric' import.
􀁺 Corrected 'Copy View' feature during remote desktop sessions.
􀁺 Added mesh view option to show wire nodes.

Hexahedral (Hex) Mesh
􀁺 Fixed metal connectivity for special geometric cases.
􀁺 Improved time step by changing the matrix calculation topology default.
􀁺 Fixed metal fillup of edges for special geometric cases.

CST MICROWAVE STUDIO - General
􀁺 Added possibility to export S-Parameters from field sources via TOUCHSTONE. New Feature!
􀁺 Fixed SAM model assembly containing coated and thin panel materials.

CST MICROWAVE STUDIO - Transient Solver (TLM Mesh)
􀁺 Solver no longer fails on Linux when an excitation signal is imported from a CSV file.

CST MICROWAVE STUDIO - Frequency Domain Solver (Tetrahedral Mesh)
􀁺 Projects created with version 2014 or earlier, that contains parameter sweeps over a scan angle of a unit cell, will no longer use the new scan angle sweep.
􀁺 Combining frequency domain solver field probe results with an AC task will no longer generate a 1D result storage error message.

CST MICROWAVE STUDIO - Integral Equation Solver
􀁺 Fixed error in calculation of acceleration token in case of MPI.
􀁺 Automatically add nearfield source excitation in special nearfield source workflow.
􀁺 Show residual plots for field source excitations.

CST CABLE STUDIO
􀁺 Avoid double scaling when loading cables from cable library in cases where there is a discrepancy with the units.
􀁺 Fixed selection of signals when changing the cable type in the 2D TL solver.
􀁺 Fixed early abort of transient simulation task.
􀁺 Avoid long simulation times after NASTRAN import which contains small gaps.

CST PCB STUDIO
􀁺 Differential selection now picks the correct component when a table containing multiple components is sorted by Net.
􀁺 Eye diagram value no longer changes when switching selected pins.
􀁺 Improved Ibis dialog box with regards to incorrect initial pin parasitics and handling of multi-selection.
􀁺 Enable highlighting of die stack components.
􀁺 Fixed licensing issue of EDA import.
􀁺 Avoid memory overflow due to missing circle deviation.
􀁺 Fixed stability issue of IR-Drop solver.
􀁺 PI Solver
􀁺 Fixed internal condition violation.
􀁺 Improved treatment of corner case during trace processing.
􀁺 Added option for exporting S-Parameters as touchstone file.
􀁺 SITD Solver
􀁺 Use half TTotal for pulse width of PRBS.
􀁺 Use an inverter spice block for differential signals.

CST BOARDCHECK
􀁺 Rule 'Net Coupling': Fixed so that the switching of parameter 'Differential Pair Coupling' has no effect.
􀁺 Improved the rule 'Critical Nets Crossing Split Reference Plane'

CST DESIGN STUDIO
􀁺 Proper update of the parameter name cache for the generation of a run ID when a parameter is renamed.
􀁺 S-Parameter results of mesh adapted runs are now correctly imported into the global CST DS cache
􀁺 Fixed remaining Wuerth device library circuit elements containing huge node numbers.
􀁺 Simulation project results from CST PCBS simulation projects are also shown in the master project.

Result Templates / VBA / Macros / External Data Access
􀁺 The template 'Field statistics template sampled' now also supports tetrahedral meshes.
􀁺 ResultReaderDLL now also works with relative path.
􀁺 New export of E and H fields to SPARK3D v1.6.1, now as post processing step for FD-TET and Eigenmode-TET based fields. (Macros > Solver > F-Solver > Export Fields to SPARK3D) New Feature!

谢谢告知!
另外有個好消息...就是keysight ADS with CST co-simulation功能在SP4里恢复了
**不知道是EMPRO进化太快了?还是ansys给的压力山大?总之是一件好事!

申明网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程

上一篇:求赋形卡式天线模型
下一篇:CST MWS如何查看远场增益图

CST培训课程推荐详情>>

  网站地图