- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
CST中材料设置问题
节录自CST 自带 Help...
Const. fit tan delta:This specification is based on a pole-zero dispersion model, defined again by the input of an electric tangent delta value given at the defined frequency and by the model order.
The first order corresponds to a Debye dispersion whereas higher order models are specifically developed to fit a broadband constant imaginary part of the permittivity. They are particularly suitable for low losses (low tangent delta value) materials. As mentioned above, at this frequency point the real part of the permittivity equals the epsilon input on the Material Parameter - General page.
If the User order checkbox is activated the model order will be selected according to the user choice. If the checkbox is deactivated the model order will be automatically determined by the fitting algorithm, selecting the best choice between optimal approximation and smallest possible number of poles.
Please note that a perfectly constant tangent delta does not exist in reality; however, the broadband behavior of this formulation represents an almost constant tangent delta curve
不懂,帮顶了
申明:网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程。
上一篇:CST瞬态仿真激励信号的时间步长问题
下一篇:CST用户自定义信号设置的问题