- 易迪拓培训,专注于微波、射频、天线设计工程师的培养
CST STUDIO SUITE 2015 Service Pack 1已发布
录入:edatop.com 点击:
CST 2015 SP1已于2月20日编译完成,今天可以在官网下载。
General / EnvironmentImproved the creation of monitors when using wavelength scheme in project templates.Fixed several issues with global locking of simulation projects.EDA Import / EDA ToolsRemoved optimization settings dialog box for the Decap Tool.Auto-correct die orientation for single dies.CST MICROWAVE STUDIO - GeneralFixed color map dB scaling.Fixed 1D plotter performance problem for pasted 1D curves.CST MICROWAVE STUDIO - Transient SolverPrevent checkout of 2 frontend license during DC optimization when port mode adaptation is active.Triangle-based surface loss calculation takes temperature-dependent materials into account.CST MICROWAVE STUDIO - Transient Solver (TLM Mesh)Output farfield and RCS probes defined using spherical coordinates as spherical vector components.Fixed solver failure for Cable Co-simulation models run via DC.CST MICROWAVE STUDIO - Frequency Domain Solver (Tetrahedral Mesh)Fixed possible crash with variable order in some cases of changing adaptation frequency.A single multipin port pin on two symmetry planes led to an error message.Field source excitation with curved mesh was inaccurate in some cases.Rotated field sources are now correctly considered.Fixed possible problems with adaptation and PML open boundaries (with fast ROM sweep).Fixed wrong field results, which occurred in some cases with fast ROM sweep.CST MICROWAVE STUDIO - Integral Equation SolverAdded check for empty excitation list to prevent undefined behavior.Fixed radiated power calculation for simulations with nearfield source excitations.Fixed problems when thin wires touch infinite ground plane.Fixed error in simulation setup when nearfield source touches PEC like sheet.CST EM STUDIO - M-Static SolverPrevent and warn if the computation of the inductances is applied to current wires.Fixed the extraction of state for zero excitations.Fixed possible heap overflow for open-boundaries.CST EM STUDIO - LF Time Domain SolverFixed long assembly times in combination with motion and several other enhancements in 2D solver.Repaired the inductance computation for voltage-driven coils.Explicitly warn if iron losses are computed on conductive domains.Fixed the stacked material model.Fixed some mesh-related problems for some settings in the user interface.CST EM STUDIO - LF Frequency Domain SolverFixed the error with temperature-dependent materials in SAM sequence context.CST PARTICLE STUDIO SolversApplied a fix for the import of hexahedral based predefined fields.CST CABLE STUDIONew cable types included in built-in library: CAT5, USB, HDMI. New Feature!Improved robustness of history list handling.Drain wire positioning now works when the outside insulator is modified.Improved the handling of existing and empty bundles regarding autobundling.Handling of existing bundles with route from curve, consider existing bundle names.Perform a complete search for sub bundle names when renaming bundle elements.Consider initial unit for stranded wires in the corresponding editor.Improved robustness of cable library handling.CST PCB STUDIORepaired wrong length-unit scaling of some PI solver input parameters.Stimulus column was turned inactive for some selected IBIS models.Voltage levels for IBIS models were wrong for some selected models.Pin groups & overlaps not optimized/cached and can result in long & redundant searches.Pin Grouping is sorting the table resulting in missing assignments.SI TD stimulus deactivated in case of open pin models. Solver ccd already handles this case.Fixed loss of current power supply pin selection when opening the corresponding dialog box for IR Drop.Improved the display of the 0D current/voltage views for IR Drop analysis.Initialization of IBIS dialog selected the wrong model resulting in unexpected simulation results.Deleting of net classes has been disabled.PI: Fixed that a vendor model that has a Touchstone file reference is treated as Spice sub-circuit model.CST DESIGN STUDIOParameter View is not activated automatically if schematic is changed.Fixed abnormal termination or Time Domain representation for FD tasks feature, when IFT is applied.Improved stability of S-Parameter task by preconditioning of Schur complement.Improved syntax check for excitation type of voltage/current sources in SPICE parser.Fixed wrong S-Parameter results for Cable Studio block with dispersive model.Version 14.0 of Filter Designer 2D integrated. New Feature!Result Templates / VBA / Macros / External Data AccessNew macro to plot farfield on uv plane (Macros > Results > Farfields > Plot 3D Farfield on UV plane). New Feature!Fixed problem with VBA command GetIndexOfLastAddedDataItem of Table object.
General / EnvironmentImproved the creation of monitors when using wavelength scheme in project templates.Fixed several issues with global locking of simulation projects.EDA Import / EDA ToolsRemoved optimization settings dialog box for the Decap Tool.Auto-correct die orientation for single dies.CST MICROWAVE STUDIO - GeneralFixed color map dB scaling.Fixed 1D plotter performance problem for pasted 1D curves.CST MICROWAVE STUDIO - Transient SolverPrevent checkout of 2 frontend license during DC optimization when port mode adaptation is active.Triangle-based surface loss calculation takes temperature-dependent materials into account.CST MICROWAVE STUDIO - Transient Solver (TLM Mesh)Output farfield and RCS probes defined using spherical coordinates as spherical vector components.Fixed solver failure for Cable Co-simulation models run via DC.CST MICROWAVE STUDIO - Frequency Domain Solver (Tetrahedral Mesh)Fixed possible crash with variable order in some cases of changing adaptation frequency.A single multipin port pin on two symmetry planes led to an error message.Field source excitation with curved mesh was inaccurate in some cases.Rotated field sources are now correctly considered.Fixed possible problems with adaptation and PML open boundaries (with fast ROM sweep).Fixed wrong field results, which occurred in some cases with fast ROM sweep.CST MICROWAVE STUDIO - Integral Equation SolverAdded check for empty excitation list to prevent undefined behavior.Fixed radiated power calculation for simulations with nearfield source excitations.Fixed problems when thin wires touch infinite ground plane.Fixed error in simulation setup when nearfield source touches PEC like sheet.CST EM STUDIO - M-Static SolverPrevent and warn if the computation of the inductances is applied to current wires.Fixed the extraction of state for zero excitations.Fixed possible heap overflow for open-boundaries.CST EM STUDIO - LF Time Domain SolverFixed long assembly times in combination with motion and several other enhancements in 2D solver.Repaired the inductance computation for voltage-driven coils.Explicitly warn if iron losses are computed on conductive domains.Fixed the stacked material model.Fixed some mesh-related problems for some settings in the user interface.CST EM STUDIO - LF Frequency Domain SolverFixed the error with temperature-dependent materials in SAM sequence context.CST PARTICLE STUDIO SolversApplied a fix for the import of hexahedral based predefined fields.CST CABLE STUDIONew cable types included in built-in library: CAT5, USB, HDMI. New Feature!Improved robustness of history list handling.Drain wire positioning now works when the outside insulator is modified.Improved the handling of existing and empty bundles regarding autobundling.Handling of existing bundles with route from curve, consider existing bundle names.Perform a complete search for sub bundle names when renaming bundle elements.Consider initial unit for stranded wires in the corresponding editor.Improved robustness of cable library handling.CST PCB STUDIORepaired wrong length-unit scaling of some PI solver input parameters.Stimulus column was turned inactive for some selected IBIS models.Voltage levels for IBIS models were wrong for some selected models.Pin groups & overlaps not optimized/cached and can result in long & redundant searches.Pin Grouping is sorting the table resulting in missing assignments.SI TD stimulus deactivated in case of open pin models. Solver ccd already handles this case.Fixed loss of current power supply pin selection when opening the corresponding dialog box for IR Drop.Improved the display of the 0D current/voltage views for IR Drop analysis.Initialization of IBIS dialog selected the wrong model resulting in unexpected simulation results.Deleting of net classes has been disabled.PI: Fixed that a vendor model that has a Touchstone file reference is treated as Spice sub-circuit model.CST DESIGN STUDIOParameter View is not activated automatically if schematic is changed.Fixed abnormal termination or Time Domain representation for FD tasks feature, when IFT is applied.Improved stability of S-Parameter task by preconditioning of Schur complement.Improved syntax check for excitation type of voltage/current sources in SPICE parser.Fixed wrong S-Parameter results for Cable Studio block with dispersive model.Version 14.0 of Filter Designer 2D integrated. New Feature!Result Templates / VBA / Macros / External Data AccessNew macro to plot farfield on uv plane (Macros > Results > Farfields > Plot 3D Farfield on UV plane). New Feature!Fixed problem with VBA command GetIndexOfLastAddedDataItem of Table object.
好厉害的样子。期待2015
英文官网怎么注册啊。
是山寨版的使用者,切勿屁股痒...
Licence文件里有。如果你没有licence,我就无能为力了……。
没必要追求新软件
嗷嗷。明白了。谢谢
2015还么有。
改进不少啊,关注!!
用了 感觉和2014也没有多大区别
申明:网友回复良莠不齐,仅供参考。如需专业解答,请学习易迪拓培训专家讲授的CST视频培训教程。